3.2. Initial setting of the predictive maintenance function

Set how to notify when consumption or abnormality of a part is detected.
Specify such as the detection level for warning occurrence, and the notification method (presence of
warning/signal output, notification day).
If you have not set the notification method, upon starting the predictive maintenance function, the
[Setting] - [Synthesis] screen appears.
[Note] In the default setting, notification is disabled. Make sure to set according to your environment.

3.2.1. Setting how to notify

7
Set the notification method.
1) From the RT ToolBox3 project tree, double-click [Online] - [Maintenance] - [Predictive Maintenance].
2) From the predictive maintenance tree, click [Setting] - [Synthesis].
* If you have not set the notification method, upon clicking [Predictive Maintenance],
the [Setting] - [Synthesis] screen appears.
2) Notification day
3) Notification
interval
4) Abnormality detection
notification method
Predictive maintenance becomes available after setting the notification method.
1) Consumption degree notification method:
Set how to notify consumption of maintenance parts and overhaul parts. You can select Warning
Occurrence or Signal Output, or both.
Warning Occurrence ... A warning occurs and the error number and error message are displayed
Signal Output ... The status can be checked with dedicated output signals.
(Setting of signal numbers are required. Refer to "3.2.3 Setting signals".)
2) Notification day:
Warning Remaining Number of Days: Set the number of remaining days for warning to occur.
Operation Time of a Day: Set the number of hours of operation of the robot per day.
3) Notification interval: Set the interval of notification of warning.
Startup and initial settings 34
[Setting] - [Synthesis] screen
according to the situation.
6) Write
1) Consumption
degree calculation
5) Level setting