14
. BATTERY/CHARGING SYSTEM/

A.C. GENERATOR

A.C. GENERATOR CHARGING
COIL
The inspection of A.C. generator charging
coil can be made with the engine installed.
INSPECTION
Disconnect the A.C. generator 2P connector.
Measure the resistance between the A.C.
generator white wire and engine ground with
an electric tester.
Standard: 0.1~1.0(at 20℃)
Replace the A.C. generator charging coil if
the reading is not within the specifications.
A.C. GENERATOR
REMOVAL
Remove the right side cover. (  2-4)
Remove the four bolts attaching the cooling
fan cover to remove the fan cover.
Charging Coil Wire
Fan Cover
Super 8 50
14-6