Section 5 BUFFER MEMORY
Table 5.1-2 Measurement sections (Un\G100 to Un\G2999) (6/6)
Address
Item
(Decimal)
Voltage
1400
Multiplying factor of voltage harmonic distortion
harmonic
1401
System area
distortion
1402
1-2 voltage harmonic distortion (3rd)
1403
1-2 voltage harmonic distortion (5th)
1404
1-2 voltage harmonic distortion (7th)
1405
1-2 voltage harmonic distortion (9th)
1406
1-2 voltage harmonic distortion (11th)
1407
1-2 voltage harmonic distortion (13th)
1408
1-2 voltage harmonic distortion (15th)
1409
1-2 voltage harmonic distortion (17th)
1410
1-2 voltage harmonic distortion (19th)
1411
1-2 voltage harmonic distortion (Total)
1412 -
System area
1419
1420
2-3 voltage harmonic distortion (3rd)
1421
2-3 voltage harmonic distortion (5th)
1422
2-3 voltage harmonic distortion (7th)
1423
2-3 voltage harmonic distortion (9th)
1424
2-3 voltage harmonic distortion (11th)
1425
2-3 voltage harmonic distortion (13th)
1426
2-3 voltage harmonic distortion (15th)
1427
2-3 voltage harmonic distortion (17th)
1428
2-3 voltage harmonic distortion (19th)
1429
2-3 voltage harmonic distortion (Total)
1430 -
System area
1599
Current
1600
Multiplying factor of current harmonic distortion
harmonic
1601
System area
distortion
1602
Phase 1 current harmonic distortion (3rd)
1603
Phase 1 current harmonic distortion (5th)
1604
Phase 1 current harmonic distortion (7th)
1605
Phase 1 current harmonic distortion (9th)
1606
Phase 1 current harmonic distortion (11th)
1607
Phase 1 current harmonic distortion (13th)
1608
Phase 1 current harmonic distortion (15th)
1609
Phase 1 current harmonic distortion (17th)
1610
Phase 1 current harmonic distortion (19th)
1611
Phase 1 current harmonic distortion (Total)
1612 -
System area
1639
1640
Phase 3 current harmonic distortion (3rd)
1641
Phase 3 current harmonic distortion (5th)
1642
Phase 3 current harmonic distortion (7th)
1643
Phase 3 current harmonic distortion (9th)
1644
Phase 3 current harmonic distortion (11th)
1645
Phase 3 current harmonic distortion (13th)
1646
Phase 3 current harmonic distortion (15th)
1647
Phase 3 current harmonic distortion (17th)
1648
Phase 3 current harmonic distortion (19th)
1649
Phase 3 current harmonic distortion (Total)
1650 -
System area
2999
*1: Even if the power failure is restored, data is held because data is backed up by the nonvolatile memory.
*2: For the procedure for using the test mode, refer to "3.4.5".
Description
57
RE81WH
Output value
Default
Back
R/W
during the
value
up
*1
test mode
-1
R
×
-
-
-
-
R
×
-
R
×
-
R
×
-
R
×
-
R
×
-
R
×
-
R
×
-
R
×
-
R
×
-
R
×
-
-
-
-
R
×
-
R
×
-
R
×
-
R
×
-
R
×
-
R
×
-
R
×
-
R
×
-
R
×
-
R
×
-
-
-
-1
R
×
-
-
-
-
R
×
-
R
×
-
R
×
-
R
×
-
R
×
-
R
×
-
R
×
-
R
×
-
R
×
-
R
×
-
-
-
-
R
×
-
R
×
-
R
×
-
R
×
-
R
×
-
R
×
-
R
-
R
×
-
R
×
-
R
×
-
-
-
*2
-1
-
4103
4105
4107
4109
4111
4113
4115
4117
4119
4120
-
4203
4205
4207
4209
4211
4213
4215
4217
4219
4220
-
-1
-
6103
6105
6107
6109
6111
6113
6115
6117
6119
6120
-
6203
6205
6207
6209
6211
6213
6215
6217
6219
6220
-

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Melsec re81wh

Table of Contents