Lucent Technologies DEFINITY AUDIX Installation And Administration Manual page 146

For g3i/g3s/g3vs/r5vs/r5si/prologix switches, tn2181 emulation, display set integration
Hide thumbs Also See for DEFINITY AUDIX:
Table of Contents

Advertisement

Installation and Switch Administration for G3i/G3s/G3vs/R5vs/R5si/ProLogix
Switches, TN2181 Emulation, Display Set Integration 585-300-122
10
Customer Acceptance
Alarm Origination Administration Test and Status MO Disk
7. If all the fields are properly filled in, press
This completes the alarm origination test.
8. Verify the status of the add mo-disk function performed in
mo-disk followed by
The system displays the Status MO-Disk screen.
Figure 10-3. Status MO-Disk Screen
b. Check that the Product Identification Number on the System-Parameters
Maintenance screen is correct
c. Enter the test alarm-origination command, terminate the session, and
hang up.
d. Check the appropriate trouble ticket. The trouble ticket should show INADS,
n, MINOR in the description field to indicate that a minor off-board alarm
was reported to INADS. There may be additional text in the description field
if other resolved alarms were reported.
e. Make a second call, log in to the DEFINITY AUDIX system, and check the
error log to verify that there are no problems.
f. T erminate the session and hang up.
RETURN
.
(Cancel) to exit the screen.
F1
.
Issue 1
May 1999
10-4
T ask
5-3, by typing status