Lens Shift Calibration - Barco Medea series Installation Manual

Table of Contents

Advertisement

Lenses
2
1
Image 5-10
3.
Turn the lens assembly to the left (CCW) (Image 5-10, Action arrow 2).
4.
Pull the lens assembly straight out of the projector lens mount (Image 5-10, Action arrow 3).
5.
Push on the button (Image 5-11, Action arrow 4) situated on the adapter to release the lens.
Image 5-11
6.
Turn the lens to the left (CCW) (Image 5-11, Action arrow 5).
7.
Pull the lens straight out of the adaptor (Image 5-11, Action arrow 6).
8.
Install the protective cap on the lens bayonet end.

5.4 Lens Shift Calibration

About lens shift calibration
The lens shift calibration consists in moving the lens in a reference point then returns it to its original position.
This operation allows to secure future actions on the lens shift.
Each time a lens shift is manually adjusted or a service intervention is done, it's necessary to realize lens shift
calibration.
Due to mechanical limitations, it is not possible to perform lens shift calibration while a lens adaptor
is inserted. If calibration is needed with lenses equipped with adapter (FLDX, FLD+,...), please
remove lens, including adaptor first.
How to calibrate
First lens shift calibration is done in Production, but execute this operation at any time is possible by using the
OSD interface (System Settings → Maintenance → Lens Calibration).
44
R5906141 /02
Medea series
2
2
3