Technical data, maintenance, disposal

9
Technical data, maintenance, disposal
Electrical data
Maintenance
Disposal of Used Parts
46
Voltage input
Measuring range
Accuracy
Resolution
Input voltage protected against incorrect polarity and return of
electric energy to ± 30 V.
Switchable voltage output
Output voltage
Output voltage protected against incorrect polarity and return of
electric energy to ± 30 V.
Galvanic Isolation to the delta
approx. 55mA (51 mA - 58 mA).
Deactivation with short circuit (approx. 70 mA) due to foldback and
by software. Reactivation using software.
The control module delta
NOTICE!
Regulations governing disposal of used parts
Note the current national regulations and legal
standards which apply in your country
ProMinent Dosiertechnik, Heidelberg / Germany is prepared to
take back the decontaminated and cleaned used parts.
The current valid Declaration of Decontamination can be obtained
www.prominent.com .
as download at
Value
0/4 mA - 25 mA (at 50 Ohm
measurement resistor)
After calibrating ± 0.5% of the
measuring range transmitting
value at calibration temperature
10-12 Bit
Value
22.5V-26V load dependent, <
50 Ohm; maximum 50mA
®
front panel. Load current limiting to
®
is maintenance free.