Mahindra Bolero Maxitruck Plus BS III 2013 Diagnostic Manual page 61

Table of Contents

Advertisement

DIAGNOSTIC MANUAL
STEP 6
Check whether the crankshaft
speed sensor wire routing is
closer to starter motor
Suspect crankshaft speed
sensor internal failure
Replace crankshaft speed
sensor with a with a new one.
Check and verify for any new
DTC's
The repair methods given by the manufacturer in this document are based on the technical specifications, current at the time of release. The methods may be modified as a result of changes introduced by the
manufacturer in the production of the various component units and accessories from which the vehicles are manufactured. The reproduction, translation, transmission, in part of or whole of the present document,
are prohibited without the prior written consent of Mahindra & Mahindra Ltd. The use of this document by any person other than the trained personnel, at the Authorized Service Centre of Mahindra & Mahindra Ltd.,
will amount to unauthorized use and shall be liable for penalty/prosecution© 2013 Mahindra & Mahindra Ltd. 
 
 
EMS
STEP 5
Check for any damage on the
flywheel
Is there any
damage/screws
loosened?
Is the wire closer to
starter motor?
MAN-00226
MAY 2013/Rev 1
P 0336
If the screws are loosened ,
tighten to torque
If toner wheel damaged, replace
it with a new one
Clear the DTC and verify
Route the wires correctly
(Refer wiring manual for proper
routing)
Clear the DTC and verify
60

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bolero maxitruck plus bs iv 2013

Table of Contents