Mahindra Bolero Maxitruck Plus BS III 2013 Diagnostic Manual page 14

Table of Contents

Advertisement

DIAGNOSTIC MANUAL
 
WATER IN FUEL
SENSOR
CONTINIOUS
TORQUE
MONITORING
CONTINUOUS
TORQUE
MONITORING
GNS
GNS RELAY
STARTER RELAY
ECU
T50
BATTERY
The repair methods given by the manufacturer in this document are based on the technical specifications, current at the time of release. The methods may be modified as a result of changes introduced by the
manufacturer in the production of the various component units and accessories from which the vehicles are manufactured. The reproduction, translation, transmission, in part of or whole of the present document,
are prohibited without the prior written consent of Mahindra & Mahindra Ltd. The use of this document by any person other than the trained personnel, at the Authorized Service Centre of Mahindra & Mahindra Ltd.,
will amount to unauthorized use and shall be liable for penalty/prosecution© 2013 Mahindra & Mahindra Ltd. 
 
 
EMS
P2269
WATER PRESENCE IN FUEL ERROR
P2265
WATER IN FUEL SENSOR FAULTY
P1900
NTP error in ADC monitoring
P163B
ECU Monitoring: ADC test error
P163C
ECU Monitoring: Voltage ratio error in ADC
P1621
ECU Monitoring: Query response communication error
P1622
ECU Monitoring: SPI communication error
P0605
ECU Monitoring: ROM memory error
P1623
ECU Monitoring: CPU error
P1625
ECU Monitoring: Response time error in ECU
ECU Monitoring: Shut off path test SPI communication
P1626
error
P1628
ECU Monitoring: Shut off path under voltage error
P1629
ECU Monitoring: WDA not working
P162A
ECU Monitoring: Time out error
P162C
ECU Monitoring: Positive test failure error
P162D
ECU Monitoring: Time out error for shut off path test
P060D
ECU Monitoring: Accelerator position error
ECU Monitoring: Engine speed error
P061C
ECU Monitoring: Rail pressure monitoring plausibility
P1638
error
ECU Monitoring: Energising time plausibility error
P060A
P1631
ECU Monitoring: Start of Injection plausibility error
P1632
ECU Monitoring: ZFC non plausibility error
P1704
GEAR NEUTRAL SIGNAL IS NOT PLAUSIBLE
P1712
GNS RELAY NO LOAD
P1713
GNS RELAY SHORT TO BATTERY ERROR
P1714
GNS RELAY SHORT TO GROUND ERROR
P1716
GNS RELAY PLAUSIBLE ERROR
P170F
STARTER RELAY OPEN LOAD
P170D
STARTER RELAY SHORT CIRCUIT TO BATTERY ERROR
P170E
STARTER RELAY SHORT CIRCUIT TO GROUND ERROR
P1641
SOFTWARE RESET ERROR
P1707
T50 signal error
SIGNAL RANGE CHECK FOR BATTERY SENSOR SIGNAL
P0071
ABOVE MAXIMUM LIMIT
SIGNAL RANGE CHECK FOR BATTERY SENSOR SIGNAL
P0562
BELOW MINIMUM LIMIT
MAN-00226
MAY 2013/Rev 1
195
197
201
202
203
204
205
207
209
211
213
215
217
219
221
223
224
225
227
13

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bolero maxitruck plus bs iv 2013

Table of Contents