Power requirements

Power requirements for the NTMW07 Trunk/Line Card are shown in
Table 40.
Table 40
Power requirements
Voltage
± 15.0 V DC
+ 8.5 V DC
- 48.0 V DC
+ 5.0 V DC

Environmental specifications

Table 41 lists the environmental specifications for the Universal Trunk Card.
Table 41
Environmental specifications
Parameter
Operating temperature
Operating humidity
Storage temperature

Foreign and surge voltage protection

The Universal Trunk Card meets CS03 overvoltage (power cross)
specifications.

Release control

Release control establishes which end of a call (near, far, either, joint, or
originating) disconnects the call. Only incoming trunks in idle ground start
configuration can provide disconnect supervision. You configure release
control for each trunk independently in the Route Data Block (LD 16).
Chapter 11 — NTMW07 Trunk/Line Card
Tolerance
± 5%
± 2%
± 5%
± 10%
Meridian 1 Option 11C Compact
Idle current
Active current
306 ma
306 ma
120 ma
120 ma
346 ma
346 ma
350 ma
350 ma
Specifications
0 to 50 degrees C, ambient
5 to 95% RH (non-condensing)
- 40 to + 70 degrees C