Mitsubishi Electric MELIPC MI5000 Series User Manual page 115

Startup
Hide thumbs Also See for MELIPC MI5000 Series:
Table of Contents

Advertisement

No.
Name
(9)
USB connector
P1
P2
P3
P4
(10)
DisplayPort
(11)
RS-232 connector
(12)
Ethernet connector
CH1
CH2
SPEED LED
SD/RD LED
(13)
CC-Link IE Field
RUN LED
Network LED
ERR LED
MST LED
D LINK LED
SD/RD LED
L ERR LED
(14)
CC-Link IE Field
L ER LED
Network connector
LINK LED
(15)
CFast card slot
(16)
Battery
Battery slot
(17)
Fan module
(18)
Terminal cover
*5
(19)
CFast/BATTERY cover
*5
(20)
Switch cover
*1 Excess load is shown in the following instances.
⋅5 V short-circuit fault within the power supply, 5 V-SG short-circuit in the main module
⋅Rated output current exceeded
⋅An increase from 5 V power supply interior, 5 V main module
*2 Flashing occurs at the following intervals.
⋅Flashing: 200 ms
⋅Flashing (low speed): 1 s
*3 Failure to replace the battery after a battery life error has occurred may result in corruption of clock data. ( Page 172 Battery
Replacement)
*4 Operate a switch using a fingertip. Use of screwdrivers or other tools may damage the switch.
*5 To prevent malfunctions, ensure that all front covers are closed when this product is in use.
Description
Connector for connection to devices supporting USB3.0.
Connector for connection to devices supporting USB2.0.
Image output connector for liquid crystal displays, etc.
Connector for connection to devices supporting RS-232.
Ethernet port managed by the VxWorks part of this product.
Connects programmable controller CPUs, SLMP compatible devices, etc.
Ethernet port managed by the Windows part of this product.
Connects to systems and devices for linkage to the cloud and other hosts.
Displays the Ethernet communications status.
• On (orange): In link-up (1000 Mbps)
• On (green): In link up (100 Mbps)
• Off: Link up (10 Mbps) or link down
Displays the Ethernet transmission/reception status.
• On: Data being sent or received
• Off: Data not sent and not received
Displays the operational status of the CC-Link IE Field Network function.
• On: Normal operation
• Off: Major error is occurring
Displays the error status of the CC-Link IE Field Network function.
• Off: Minor error is occurring, errors detected for all stations, major error is occurring (when RUN LED is off)
• Flashing: Moderate error is occurring, tethering error is detected, major error is occurring (when RUN LED is
off)
• Off: Normal operation
Displays if this product is operating as a master station or local station in the CC-Link IE Field Network.
• On: Operating as master station
• Off: Operating as local station
Displays the CC-Link IE Field Network data link status.
• On: Data link (cyclic transmission)
• Flashing: In data link (cyclic transmission stopped)
• Off: Data link not in progress (disconnected)
Displays the CC-Link IE Field Network transmission status.
• On: Data being sent or received
• Off: Data not sent and not received
Displays the CC-Link IE Field Network received data and line error status.
• On: Normal data reception and loopback not in progress
• Off: Error data received or loopback in progress
Displays the port status.
• On: Abnormal data reception
• Off: Normal data reception
Displays the link status.
• On: In link-up
• Off: In link-down
Slot for the CFast card
Backup power source to retain clock data.
Slot for battery.
Product cooling module.
A protective cover for the terminal block
Protective cover for CFast card slot and battery slot.
Protective cover for the switch section.
APPX