Appendix 4
This section lists the functions of this product.

Functions for Windows part

The following table shows the functions of the Windows part of this product.
Function
Diagnostic and maintenance functions

Functions for VxWorks part

The following table shows the functions of the VxWorks part of this product.
Function
Clock function
Programmable controller device memory function
SLMP function
iQSS function
CC-Link IE Field Network function
CC-Link IE Field Network Basic function
Diagnostic and maintenance functions
Telnet function
Network file access functions
APPX
132

Appendix 4 Function List

Function List
Watchdog timer (WDT) function
Clock setting function
Time zone setting function
Daylight saving time setting
function
Clock data synchronization setting
function
Time setting function (SNTP
client)
SLMP server functions
Self-diagnosis function
Watchdog timer (WDT) function
Operating status management
functions
Event history function
Switch/LED operation function
External device configuration
diagnostics function
Function to forcibly restart
Windows during an error
MELIPC shutdown function
Individual reset function
User drive initialization function
FTP Function
File sharing function
Description
To detect hardware errors of the Windows part of this product.
Description
To set the clock data of the clock managed by the VxWorks part.
To set the time zone of the clock managed by the VxWorks part.
To set daylight saving time (summer time) of the clock managed by the VxWorks
part.
To synchronize the clock managed by the VxWorks part and the clock managed
by the Windows part.
To collect time information at the specified time from the time information server
(SNTP server) connected to the network and automatically configures the time of
the VxWorks part of this product.
To create devices of the programmable controller CPU on the memory of this
product and enables access to the devices from external devices.
To write and read device data of the VxWorks part of this product from personal
computers, display equipment (GOT, etc.), and other SLMP-compatible devices
or the Windows part using SLMP.
To make iQ Sensor Solution (iQSS) available in this product.
To perform data communications between this product and devices on the
network through CC-Link IE Field Network.
To perform data communications between this product and devices on the
network through general Ethernet.
To diagnose this product to check errors.
To detect errors of the hardware of this product and user applications (used
programs).
To manage the operating status (including STOP/RUN status) of this product.
To collect and save the following information: errors detected by this product,
operations performed for this product, and errors occurred on a network.
To operate the LEDs, acquire the LED statuses, acquire switch statuses, and
manipulate operating statuses of this product.
To display communication statuses between the Ethernet port (CH1) of this
product and external devices, and between virtual Ethernet and the
communication target.
To forcibly restart only the Windows part without resetting this product if a freeze
or system error occurs on the Windows part or a system watchdog timer error
occurs.
To set the VxWorks part and Windows part to the state in which the power can be
turned OFF so that this product can be turned OFF.
To reset the Windows part of this product individually.
To delete all folders and files stored on the user drive of this product.
To execute shell commands by a personal computer or Telnet tool of the
Windows part using the TCP/IP network.
To run the VxWorks part of this product as an FTP server.
To run the VxWorks part of this product as a file sharing server.