Installation Of The Appliance - Westinghouse WFE904SC User Manual

900mm cooking appliances
Table of Contents

Advertisement

INSTALLATION OF THE APPLIANCE

Cabinet requirement
Models WFE904SC, WFE914SC, WFEP915SC, &
WFE946SC are designed to fit into a 900mm wide
gap between standard kitchen cabinets. The appliance
integrates with the kitchen cabinets by matching the
height, depth and kick panel. The cooker may also be
installed at the end of a line of benches or with a free
space either side. In addition, a slot-in type installation
is catered for allowing a continuous cabinetry kick
panel to be used. Models WVE914SB, WVE916SB and
WVEP916SB are designed to be built into cabinetry
either below a benchtop or into a vertical cabinet.
WARNING
WARNING
• The cooker must be installed and serviced only
by an authorised person.
• A Certificate of Compliance MUST be supplied to
be kept by the customer.
• The packing materials must be removed before
you install the cooker.
• The surrounding kitchen cabinets must be able
to withstand 85°C. Electrolux WILL NOT accept
responsibility for damage caused by installation
into kitchen cabinets which cannot withstand 85°C.
• The pipes used for installation MUST have sufficient
loops so the cooker can be moved for service
(gas models).
• The vents, openings and air spaces MUST NOT
be blocked.
• Two anti-tilt brackets are supplied and stored in the
base of the packaging
• The anti-tilt brackets and chain or front stops
MUST be installed to avoid accidental tipping
(freestanding and slot-in models).
• You MUST NOT lift or pull the cooker by the
door handle.
• The cooker MUST be checked every five years.
• If the supply cord is damaged,it must be replaced
by the manufacturer, its service agent or similarly
qualified persons in order to avoid a hazard.
• The appliance must not be installed behind a
decorative door in order to avoid overheating.
• Due to the weight (95-100kg) and size of the
cooker, 2 persons are required to install it.
40
INSTALLATION OF THE APPLIANCE
Gas model clearance requirements
• Ensure the appliance is installed in accordance with
clauses 6.2.5 and 6.10.1.1 of AS/NZS 5601.1 or clauses
6.9.1 and 6.9.5 of AS/NZS 5601.2 with regard to
clearances to combustible surfaces and materials,
and clearances to rangehoods and exhaust fans,
to ensure clearances of 200mm from burners to
vertical combustible surfaces observe the minimum
dimension of 100mm from each side of the cooker to
combustible surfaces.
• Clearances to combustible surfaces may be reduced
if combustible surfaces are protected in accordance
with clause 6.10.1.2 of AS/NZS 5601.1, or clause 6.9.2
of AS/NZS 5601.2.
• When setting the cooker height, ensure the top of
the cooker is at least 10mm higher than the level of
the benchtop.
Dimensions
600mm minimum
vertical clearance
from combustible
surfaces
Gas hob 910mm
(adjustable 910-930mm)
Ceramic hob 906mm
(adjustable 906-926mm)
15mm
(height of trivet above hob)