Installer manual Autotrol 368 (604-606) - Installation
2. Push the water line connectors (3) into the bypass and valve. This will help release O-rings
that may have seated in place.
3. Remove the clips (1) by inserting a flat screwdriver (2) under the top centre of the clip and
lifting (prying up).
Caution - material
Do not use pliers to remove a clip.
It is likely the clip will break.
5.9

Drain line connection

Info
Standard commercial practices are expressed here.
Local codes may require changes to the following suggestions.
Check with local authorities before installing a system.
Mandatory
The drain line must be build with ½" semi rigid or rigid piping ! An air gap must be
present at the drain!
28 / 60
Ref. MKT-IM-007 / D - 09.10.2020