Uncompensated Pvb With Load Drop Check Valve - Danfoss PVG-EX 32 Technical Information

Proportional valve group
Table of Contents

Advertisement

Technical Information
PVG-EX 32 Proportional Valve Group
PVB Basic Modules

Uncompensated PVB with load drop check valve

42 |
©
Danfoss | June 2019
The uncompensated PVB is intended for controlling a work function where the function behavior in
terms of flow and pressures allows dependency on the load pressure of other functions used
simultaneously. The integrated load drop check valve prevents flow back from work ports influencing
other functions.
The Uncompensated PVB with load drop check valve features:
Integrated LS shuttle network
Load drop check valve
Optional shock/anti-cavitation valve facility (PVLP)
Optional LS
shuttle valve facility for float spool use
A/B
Optional T0 facility
Schematic
1
0
2
Technical specification for A/B-port
Max. continuous pressure
350 bar [5076 psi]
Technical specification
Parameter
Fluid temperature
Fluid viscosity
Fluid cleanliness
Operating temperature
A
B
Max. intermittent pressure
420 bar [6090 psi]
Minimum
Recommended range
-30°C [-22°F]
30 to 60°C [86 to 140°F]
2
4 mm
/s [39 SUS]
12 to 75 mm
23/19/16 (according to ISO 4406)
Ambient: -30 to 60°C [-22 to 140°F]
Max. rated flow
125 l/min [33 US gal/min]
Maximum
90° [194°F]
2
2
/s [65 to 347 SUS]
460 mm
/s [2128 SUS]
BC290860493426en-000103