Uncompensated Pvbz With Poc - Danfoss PVG-EX 32 Technical Information

Proportional valve group
Table of Contents

Advertisement

Technical Information
PVG-EX 32 Proportional Valve Group
PVB Basic Modules

Uncompensated PVBZ with POC

©
Danfoss | June 2019
The uncompensated PVBZ is intended for controlling a work function where the function behavior in
terms of flow and pressures allows dependency on the load pressure of other functions used
simultaneously.
The Pilot Operated Check valve giving very low leakage will prevent cylinder creep.
The Uncompensated PVBZ with POC features:
Integrated LS shuttle network
Integrated POC
Optional T0 facility
Schematic
1
0
2
Technical specification for A/B-port
Max. continuous pressure
350 bar [5076 psi]
Technical specification
Parameter
Fluid temperature
Fluid viscosity
Fluid cleanliness
Operating temperature
Part numbers for uncompensated PVBZ with POC
Part number
157B6051
157B6052
157B6451
157B6452
157B6969
A
B
Max. intermittent pressure
420 bar [6090 psi]
Minimum
Recommended range
-30°C [-22°F]
30 to 60°C [86 to 140°F]
2
4 mm
/s [39 SUS]
12 to 75 mm
23/19/16 (according to ISO 4406)
Ambient: -30 to 60°C [-22 to 140°F]
A/B-port
G½"
7/8–14 UNF
None – machined top
Max. rated flow
125 l/min [33 US gal/min]
Maximum
90° [194°F]
2
2
/s [65 to 347 SUS]
460 mm
/s [2128 SUS]
POC
B-port
A/B-port
B-port
A/B-port
A-port
BC290860493426en-000103 | 45

Advertisement

Table of Contents
loading

Table of Contents