Danfoss PVG-EX 32 Technical Information page 40

Proportional valve group
Table of Contents

Advertisement

Technical Information
PVG-EX 32 Proportional Valve Group
PVB Basic Modules
40 |
©
Danfoss | June 2019
Performance graphs (Theoretical)
PVLP shock valve characteristics
P
[psi]
(bar)
6000
400
5000
350
300
4000
250
3000
200
150
2000
100
1000
50
0
0
0
20
40
60
10
15
20
0
5
PVLP/PVLA suction valve characteristics
P
P
[psi]
[bar]
28
400
26
360
24
320
22
20
280
18
240
16
200
14
12
160
10
120
8
6
80
4
40
2
0
0
0
5
10 15 20 25 30 35 40 45
0
1 2 3 4 5
6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21
Part numbers for uncompensated PVB
Part number
A/B-port
157B6000
157B6010
G1/2"
157B6030
11071832
Q
80
100
120
140
(l/min)
Q
25
30
35
40
45
[US gal/min]
50 55 60 65
70 75 80
PVLP/PVLA
Yes
Yes
PVLP
PVLA
85 90 95 100
105 110 115 120
[l/min]
[US gal/min]
22 23 24 25 26
27 28 29 30 31
LS A/B shuttle
T0 facility
Yes
Yes
BC290860493426en-000103
Q
Q

Advertisement

Table of Contents
loading

Table of Contents