Pvb With Pressure Compensation, Closed Center Pvp - Danfoss PVG 100 Technical Information

Proportional valve group
Hide thumbs Also See for PVG 100:
Table of Contents

Advertisement

Technical Information
PVG 100 Proportional Valve Group
Technical characteristics

PVB with pressure compensation, closed center PVP

30 |
©
Danfoss | May 2018
Pressure drop PVB for open spool in neutral position
D
D
p
p
A/B
T neutral open center spool
psi
bar
100 130
3500
250
40/65
3000
200
2500
160
2000
120
1500
80
1000
40
500
0
0
0
10
20
30
0
2
4
6
8
Oil flow as a function of spool travel for spools A to F - 20 bar [290 psi]
Q
Q
A/B
A/B
US
l/min
P
gal/min
250
60
225
200
50
175
40
150
125
30
100
20
75
50
10
25
0
0
0
1
2
3
0
0.04
0.08
0.12
5
7
9
73
100
130
0.50
0.55
0.60
Set pressure difference between pump pressure and LS signal = 20 bar [290 psi] measured at the P-port
of the valve.
150/180
Q
A/B
40
50
l/min
Q
A/B
US gal/min
10
12
14
V310204.A
A/B
F
E
D
C
B
A
a
4
5
6
7
mm
a
0.16
0.20
0.24
0.28
in
p
11
13
15
bar
p
psi
160
190
218
U
s
U
0.65
0.70
0.75
DC
157-689.11
PVM
PVM
PVH
PVH
PVE
520L0720 | BC00000039en-US0502