Dampened Compensated Pvb - Danfoss PVG-EX 32 Technical Information

Proportional valve group
Table of Contents

Advertisement

Technical Information
PVG-EX 32 Proportional Valve Group
PVB Basic Modules

Dampened Compensated PVB

©
Danfoss | June 2019
The compensated PVB is intended for controlling a work function where the function behavior in terms
of flow and pressures requires independence on the load pressure of other functions used
simultaneously. The dampening of the compensator reaction will slow down the system thereby
removing instability.
The dampened compensated PVB features:
Integrated LS shuttle network
Integrated compensator
Optional shock/anti-cavitation valve facility (PVLP)
Compensated PVB schematic
T P LX
1
0
2
Technical specification for A/B-port
Max. continuous pressure
350 bar [5076 psi]
*
With turbo function spool @ max rated flow of 130 l/min is possible
Technical specification
Parameter
Fluid temperature
Fluid viscosity
Fluid cleanliness
Operating temperature
Pp
A
B
Max. intermittent pressure
420 bar [6090 psi]
Minimum
Recommended range
-30°C [-22°F]
30 to 60°C [86 to 140°F]
2
4 mm
/s [39 SUS]
12 to 75 mm
23/19/16 (according to ISO 4406)
Ambient: -30 to 60°C [-22 to 140°F]
*
Max. rated flow
125 l/min [33 US gal/min]
Maximum
90° [194°F]
2
2
/s [65 to 347 SUS]
460 mm
/s [2128 SUS]
BC290860493426en-000103 | 49