Download Print this page

Beretta EXCLUSIVE C Series Installation And User Manual page 40

Gas adaptive condensing boiler
Hide thumbs Also See for EXCLUSIVE C Series:

Advertisement

EXCLUSIVE
Parameter
Seasonal space heating energy efficiency class
Water heating energy efficiency class
Rated heat output
Seasonal space heating energy efficiency
Useful heat output
At rated heat output and high-temperature regime (*)
At 30% of rated heat output and low-temperature re-
gime (**)
Useful efficiency
At rated heat output and high-temperature regime (*)
At 30% of rated heat output and low-temperature re-
gime (**)
Auxiliary electricity consumption
At full load
At part load
In Stand-by mode
Other parameters
Stand-by heat loss
Pilot lame energy consumption
Annual energy consumption
Sound power level, indoors
Emissions of nitrogen oxides
For combination heaters
Declared load profile
Water heating energy efficiency
Daily electricity consumption
Daily fuel consumption
Annual electricity consumption
Annual fuel consumption
(*) High-temperature regime means 60 °C return temperature at heater inlet and 80 °C feed temperature at heater outlet.
(**) Low temperature means for condensing boilers 30 °C, for low-temperature boilers 37 °C and for other heaters 50 °C return
temperature (at heater inlet).
INSTALLER -
Conditional Warranty
This appliance is a sophisticated piece of equipment it is designed to give long term reliable service when
maintained as intended It may fail prematurely if it is not serviced. Service is a legal requirement in the EU
The NZ warranty on this appliance is conditional upon annual service being carried out. Where service is
not carried out the manufacture/distributor accepts no liability for any failure that could be associated to a
lack of maintenance.
This includes but not exclusively Sensors electrodes heat exchangers and safety devices.
Note servicing of this appliance should only be carried out by a competent engineer with detailed
knowledge and training – Commissioning and servicing Training is available in NZ through the distributors.
A schedule of service requirements is shown on page 28. Please note the requirement to replace the burner chamber
seal at each service
Labour allowances under the appliance warranty
rounded up to the hour plus 1 hour for diagnosis, This is a fair representation of the time that an experienced
competent engineer would require to rectify a fault (Travel expensed are limited to the terms set out by the distributor)
(call out charges will only be covered in case of immediate danger to life or property)
40
USER
- SERVICE ENGINEER - PLEASE NOTE
Service invoice records must be made available when making a claim.
EXCLUSIVE
Symbol
25C
-
A
-
A
Pnominal
18
ηs
94
P4
17.6
P1
5.9
η4
88.2
η1
98.9
elmax
28.0
elmin
14.0
PSB
3.0
Pstby
42.0
Pign
-
QHE
37
LWA
51
NOx
46
XL
ηwh
86
Qelec
0.127
Qfuel
22.777
AEC
28
AFC
17
is limited to the manufacturers schedule of time allowances
EXCLUSIVE
EXCLUSIVE
30C
35C
A
A
A
A
24
29
94
94
23.5
29.4
7.9
9.8
88.3
88.1
98.9
98.6
37.0
40.0
14.0
14.0
3.0
3.0
42.0
37.0
-
-
42
52
53
-
33
41
XL
XL
85
85
0.167
0.148
22.921
23.093
37
32
17
17
Unit
-
-
kW
%
kW
kW
%
%
W
W
W
W
W
GJ
dB
mg/kWh
%
kWh
kWh
kWh
GJ

Advertisement

loading

This manual is also suitable for: