Beretta EXCLUSIVE C Series Installation And User Manual page 26

Gas adaptive condensing boiler
Hide thumbs Also See for EXCLUSIVE C Series:

Advertisement

EXCLUSIVE
ZONES MANAGER
SENSOR CALIBRATION
SYSTEM RESET
INSTALLER
- Select CONFIRM to conform the system reset or else CANCEL to
cancel the operation.
Note: after a reset it is necessary to carry out a new configuration of the
system; for details about this procedure, see the following section.
5.20
System Re configuration
This operation must be carried out only by a competent engineer
After a "SYSTEM RESET", the control displays an initial screen
showing the firmware revision. Pressing "ok" a guided procedure is
started for configuring the system; select the desired options with the
"up" and "down" keys, confirming the selections made:
MULTI ZONE CONTROLLER
REC10 V01.26
PRESS ANY KEY
TO CONTINUE
- LANGUAGE selection:
ENGLISH
ITALIANO
26
INSTALL
CONFIRM
CANCEL
( after Reset)
ENGLISH
ITALIANO
- setting TIME and DATE
ENTER TIME AND DATE
12
18 / 11 / 2013
USE THE ARROWS TO MODIFY
- Setting the operating mode of the REC10:
Select MASTER when a replacement REC10 is the integral boiler interface
- Configuration selection:
Use NEW: to set a new system configuration if restoring the factory
setting of the parameters
With "NEW" configuration selected, proceed as follows:
- select REC10 functionality:
Select ON BOARD: The REC10 is used as a system interface and not as
A Zone regulator
AMBIENT: used only if another REC10 is used as a separate system
interface as an ambient regulator of the zone to which it is installed
THE REC10 INSTALLED?
- Select the type of boiler =INSTANTANEOUS (the boiler is the combined
heat and hot water variety)
INSTANTANEOUS
STORAGE TANK
SELECT THE PLANT
TIME & DATE
:
17
SELECT THE TYPE
OF CONFIGURATION
FROM AKM
NEW
BOILER
WHERE IS
ON BOARD
AMBIENT
PLANT
CH ONLY
CONFIGURATION