1
WARNINGS AND SAFETY
The boilers manufactured are inspected in the smallest detail in
order to protect users and installers against possible injury. After
installation check the electrical wiring, in particular stripped parts of
leads, which must not protrude from the terminal boards
This installer and user manual constitutes an integral part of this
product.. Make sure it is always kept with the appliance, even if it
is transferred to another owner or user, or moved to another heating
system. In case of loss or damage, please contact Heat IQ Technical
Assistance for a new copy.
This boiler may only be installed and serviced by personnel qualified
in accordance with current regulations.
The installer must instruct the user in the operation of the
appliance and about essential safety
This boiler must only be used for the application it was designed for.
The manufacturer accepts no liability within or without the contract
for any damage caused to people, animals and property due to
installation, adjustment and maintenance errors or to improper use.
After removing the packaging, make sure the content is in good
condition and complete. If not, contact the supplier immediately.
The safety valve outlet must be connected to a suitable collection
and drain system. The manufacturer declines all liability for damage
caused due to any intervention carried out to the safety valve.
The seal of the condensate drainage connection line must be fully
protected against the risk of freezing
Check that the rain water drainage channel of the flue and the
relative connection pipe are free of obstructions.
Dispose of waste by being careful not to harm human health and
without employing procedures or methods which may damage the
environment.
At the end of its life, the product should be not be disposed of as solid
urban waste, but rather it should be recycled.
During installation, inform the user that:
- In the event of water leaks, the water supply must be shut off and
the Installer contacted immediately
- Periodically check that the operating pressure of the hydraulic
system is between 1 and 1.5 bar. If it is not, contact the installer
If the boiler is unused for a long period we recommended
-
Turn the main appliance switch and the main system switch to "off"
-
Close the fuel and water valves for the heating and domestic hot
water system
Drain if there is a risk of freezing
Boiler maintenance must be carried out at least once a
s e r v i c i n g m u s t b e c a r r i e d o u t by a suitably qualified
competent engineer
The appliance is not to be used by children
It is forbidden to touch the appliance while barefoot or if parts of your
body are wet.
Do no activate electric devices or appliances such as switches,
household appliances and so on if you notice a smell of Gas. In this
case:
-
Ventilate the room by opening the doors and windows;
-
Close the fuel shut-off device;
-
Request the prompt intervention of a Gas fitter or service engineer
regulations.
year;
Any technical or cleaning operation is forbidden before isolating the
appliance from the power supply by turning the power point switch
to "OFF" and the main switch of the boiler to "OFF".
a
Do not modify the safety or adjustment devices without the
manufacturer's precise instructions.
.
Do not leave inflammable containers and substances in the room
where the appliance is installed.
Do not leave flammable containers and substances in the room
where the device is installed.
Do not leave packaging material in reach of children as it may be a
potential source of suffocation.
The condensate drain outlet must be run avoiding double trapping
Never carry out any Adjustment of the gas valve.
2

Boiler Description

EXCLUSIVE are equipped with a new ACC (Activate Combustion
Control) system.
This new control system, developed by Beretta, ensures functionality,
efficiency and low emissions under any conditions
.
The ACC system uses an ionisation sensor immersed in the
burner flame, whose information allows the control board to
operate the gas valve which regulates the fuel.
This sophisticated control system provides the auto-regulation of
the combustion, so there is no need for an initial calibration. The
ACC system is able to adapt the boiler to operate with different gas
compositions, different outlet pipes lengths and different altitudes
(within the specified design limits).
The ACC system can also perform an auto-diagnostic operation
that locks out the burner before the permitted upper emissions
limit is exceeded.
is a type C condensing wall-hung boiler to be used for
EXCLUSIVE
heating and the production of domestic hot water: depending on
the fume discharge accessory used, it is classified in categories
C13,C13x; C33,C33x; C43,C43x; C53,C53x; C63,C63x; C83,
C83x; C93, C93x.
In configurations prefix C, this appliance can be installed in any
type of room
(There are no limitations due to ventilation conditions or room
volume).