 Encoder cable
 FR-JCBL
F-DPEVSB 12P 0.2 mm
Earth cable
60 mm
Model
FR-JCBL5
FR-JCBL15
FR-JCBL30
 FR-V7CBL
F-DPEVSB 12P 0.2 mm
Earth cable
60 mm
A P clip for earthing (grounding) a shielded cable is provided.
Model
FR-V7CBL5
FR-V7CBL15
FR-V7CBL30
• As the terminal block of the FR-A8AP is an insertion type, cables need to be treated when the encoder cables of the inverter
are crimping terminals. Cut the crimp terminal of the encoder cable and strip its sheath to make its cable wires loose.
Also, treat the shielding wires of the shielded twisted pair cable to ensure that they do not contact conductive areas.
Wire the stripped cable after twisting it to prevent it from becoming loose. In addition, do not solder it.
66
2. INSTALLATION AND WIRING
2.8 Connection to a motor with encoder (Vector control)
2
D/MS3057-12A
Approx. 140 mm
L
D/MS3106B20-29S
Length L (m)
5
15
30
2
D/MS3057-12A
Approx. 140 mm
L
D/MS3106B20-29S
Length L (m)
5
15
30
Cable stripping size
5 mm
FR-A800
(FR-A8AP)
PA1
PA2
PB1
PB2
PZ1
PZ2
PG
SD
2
2 mm
FR-A800
(FR-A8AP)
PA1
PA2
PB1
PB2
PZ1
PZ2
PG
SD
2
2 mm
PLG
C
R
A
N
B
Positioning keyway
P
A B
M
N
C
H
L
D
P
K
T
K
E
S
R
J
F
H
G
D/MS3106B20-29S
(As viewed from wiring side)
PLG
A
B
C
D
F
Positioning keyway
G
A
M
B
N
C
S
L
D
P
R
T
K
E
S
R
J
F
H
G
D/MS3106B20-29S
(As viewed from wiring side)