Connection of a pH pump to the Control Center

1 - Connect pH pump and the pH corrector level sensor as described below.
NEUTRAL (N)
EARTH
PHASE (L)
The pH corrector must be placed after filtration, after the heating pump,
and after the probes.
AUX1 connection (fountain or NAC or waterfall or garden lighting, etc.)

Connection of the accessory pump to the Control Center

1 - Connect a second pump to the AUX1 outlet as described below.
Connection of a push/pull pneumatic valve
(automatic backwash) to the Control Center
1 - Connect the pneumatic valve as described below.
pH
N
L
AUX1 CL
230 V ~
3 bar min
To the lter
From the lter
pH
N
L
AUX1 CL
230 V ~
pH
N
L
AUX1 CL
230 V ~
PHASE (L)
EARTH
NEUTRAL (N)
5-230 V~
OR
BUS
PHASE (L)
EARTH
NEUTRAL (N)
5-230 V~
OR
BUS
BUS
BUS
Chlorine level sensor is normally open.
(Closed switch = empty tank)
If an installation includes a pH pump and a chlorine
pump, the pool's two chlorine level sensors must be
connected serially.
pH -
pH+
5-230 V~
OR
BUS
A1
A2
Connection of a 3-way valve
to the Control Center
1 - Connect the 3-way valve as described below.
pH
N
L
AUX1 CL
230 V ~
A1
L1
L2
pH
CL
5-230 V~
OR
BUS
PHASE (L)
EARTH
A2
NEUTRAL (N)
13