Installation of the water temperature probe

INTELLIPOOL is supplied with a temperature probe which is suitable for water. It is possible to mount a second temperature probe for the air
temperature used to manage the frost protection process of heated technical rooms.
The temperature probe can be installed outside the bypass
in front of the filter of the pump or in front of the filter inlet in
order to improve the reading precision. 1 - Pierce the PVC
pipe to a diameter of 10 mm (3/8 inch). 2 - Remove the
shavings and check that the O-ring is present under the
probe, place the probe in the hole. 3 - Place the metal clamp
in the groove and tighten.
Ø 10 mm
1

Installation of pH/ORP/Conduct. probes

1 - Completely unscrew the strain relief bushing: be careful and do not let the black, flexible seal fall.
2 - Pass the cables through the nut and strain relief bushing
3 - Connect each lug according to the indicator under each terminal block
4 - Tighten using a 2.5 mm/0.5-0.6 Nm slotted screwdriver
5 - Securely re-tighten the strain relief bushing by hand
The service life of the probes (depending on the conditions of use) is around 2 years for the pH probe, 5 years for the
RedOx probe and a lifetime for the conductivity and temperature probes. Only Pentair probes are compatible and
guarantee proper functioning of the IntelliPool®.
TO ISOLATE THE BYPASS, CLOSING THE TWO VALVES BEFORE CHANGING A PROBE IS MANDATORY TO
PREVENT ANY RISK OF FLOODING.

Mount the Control Center/Probe Unit to a wall

- This device is intended to be used inside, installed in a technical room
which cannot be accessed by children.
- Set the device at a height lower than 2 m using three screws (4 to 5 mm
diameter) in appropriate plugs for the type of support and fix the device
vertically on a clean support which is able to bear a minimum vertical load
of 5 kg.
Make three holes, with plugs, following the below dimensions.
1 - Place the upper screw and hang the device.
2 - Place the 2 lower screws.
3 - Add the 2 lower screw covers to ensure a full seal.
Placement of the Probe Unit and Control Center
The Probe Unit must be located close to the probe assembly bypass.
The Control Center must be located next to the electrical cabinet and its keypad must be accessible to easily perform settings.
8
3
2

INSTALLATION OF THE AIR TEMPERATURE PROBE (OPTION)

- If the air temperature probe is connected, it automatically becomes the reference
value for the management of the anti-freeze protection. The air temperature probe
is placed outdoors, away from direct sunlight so that the measurement is not
distorted. It can be easily moved due to its 6 m long cable.
1 – Mount it to a wall by screwing OR 2 – Mount it on a horizontal bar of a grate with
a cable tie.
NO
OK
1
2
1
If an air temperature
probe is connected,
the air temperature
information from the
radio relay will no
longer be used.
3
2