Set point menu

This menu makes it possible to fix all the set points of the connected equipment.
Some parameters can only be accessed according to the type of account
Set the Control Center to the time of the
computer
The disinfectant is selected directly at the
Control Center.
These schedule settings are only used if
the filtration is set to schedule mode in the
menu Commands.
These schedule settings are only used if
the lighting is set to schedule mode in the
menu Commands.
It may take up to 15 minutes for the
application of any modification made on the
internet to be seen on the installation.
Pool volume renewal rate
x3
x2
x1
0 °C
Set points: 45000
Pool information
Heating
AUX 1: BackWash
pH regulation
RedOx sterilisation
Filtration
Frost protection linked to the air T°:
0 h 1 h 2 h 3 h 4 h 5 h 6 h 7 h 8 h 9 h 10 h 11 h 12 h 13 h 14 h 15 h 16 h 17 h 18 h 19 h 20 h 21 h 22 h 23 h 24 h
Authorisation for pump to function in automatic mode
7 h
Start time:
pH priority:
Lighting
Choice of the colour:
Prevents the operation of the lighting with the roller shutter:
0 h 1 h 2 h 3 h 4 h 5 h 6 h 7 h 8 h 9 h 10 h 11 h 12 h 13 h 14 h 15 h 16 h 17 h 18 h 19 h 20 h 21 h 22 h 23 h 24 h
The display depends on the type of equipment connected and the options selected
: cannot be accessed from a private account Individual l
5 °C
10 °C
15 °C
Synchronise time
28
Volume:
24
Setpoint value:
backwash
Function choice:
7.3
Assignment feature:
pH-
pH corrector type:
20
Injection time:
0.3
Maximum volume:
0.3
Threshold:
700
Setpoint value:
Chlorinator
Disinfectant type:
15
Threshold:
3
Frost protection:
30
Economy mode:
30
Turbo mode:
1m 30s
Wash time:
30 sec
Filter rinse time:
260
Filtration duration before alert:
Daily timer programming
Auto
End time:
ORP priority:
Heating priority:
Caribbean Mode
Daily timer programming
Save modifications
20 °C
25 °C
30 °C
Heating pump value to be achieved in AUTO
mode in the menu Commands.
3
m
pH value to be achieved in AUTO mode in the
menu Commands
°C
- The selection between pH- and pH+ is directly
accessible at the Control Center.
- This selection is not accessible from a private
account.
s
RedOx value to be achieved in AUTO mode in
L/d
the menu Commands.
°C
mV
Anti-freezing value.
°C
This setting makes it possible to limit the time
°C
window of filtration to ensure that it does not
function at inappropriate times (noise problems
%
at night in terms of neighbours, for example).
%
h
A priority makes it possible to control filtration
within the authorised time window (because this
equipment needs to function when the filtration
is in operation and within the normal time
period, this equipment is not authorised to
control filtration).
Optimal pump speed
Water temperature
35 °C
25

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents