Special Settings (Restricted) - Pentair IntelliPool User Manual

Table of Contents

Advertisement

Special settings (restricted)

This menu enables the installer to customise the settings in accordance with the particularities of an installation. Modifying these parameters may have critical
consequences for the pool. We advise you to have the modified settings checked by a professional. Access the SETTINGS MENU and simultaneously press ESC
& ENTER for 3 seconds. The sub-menu Install menu appears in the corner at the bottom right of the screen (automatically disappears after 120 minutes).
S E T TI N G S MEN U
-pH/Dis infec t. /Tem p
-La ng ua g e -Tim e
-R a dio
x1
+
ENTER
INSTALL . FI LTR ATION
Anti- fre e zin g :+3 ° C
Eco=(Stan d ard - 30 %)
Tur bo=(Stan da rd +3 0% )
Anti-freezing:
Makes it possible to modify the
minimum temperature of water
from which filtration is forced.
Eco:
Reduces the filtration time
(in %) of the duration
normally calculated.
Turbo:
Increases the filtration time
(in %) of the duration
normally calculated.
18
3 s
ESC
S E T T I N G S M E N U
+
3 s
- p H/ D i s i n fec t. /Te m p
- L an g u a ge -Ti me
ENTER
- R a d i o
- I n s t a l
x2
+
ENTER
IN STA LLATION p H
I njec tion tim e : 15sec
Tem perature min.: 25°C
Daily volume, ma x.:0.2 L
Modification of the injection
parameters of the pH corrector
Injection time:
Duration of each injection
sequence of the corrector
performed every 15 minutes by
the pH pump.
Min temperature: Temperature
below which the pH corrector is
not injected.
Volume days Max:
Maximum authorised volume of
injection of pH regulator (for a
flow pump of 1 L/h) to safeguard
against potential overdosing.
: Selects the type of disinfectant chosen.
E le c t ro l ys i s / O t h e r
Corresponds to a treatment by dosing pump (bromine, chlorine, active
oxygen, etc.)
x4
+
-Fi l trat i o n -p H
-D i s i n fe c t. -Au x 1
ENTER
D e f a u l t va l u e s
x3
+
ENTER
INSTAL. DISINFECTANT
Injection time : 15sec
Temperature min.: 15°C
Daily volume, max.:0.5L
Modification of non-electrolyser
disinfectant injection parameters
(bromine
injection,
active
oxygen)
Injection time:
Time for each disinfectant
injection sequence.
Min temperature: Temperature
below which the disinfectant is
not injected or the electrolyser is
stopped to the limit wear of the
plates.
Volume days Max:
Maximum authorised volume of
disinfectant (for a flow pump of 1
L/h) to safeguard against
potential overdosing.
E l e c t ro l ys is /O t h e r
x4
+
ENTER
INS TAL L ATIO N AU X 1
R o bo t mo d e : No
B a c k wash m od e: No
B a c k wash temp o: 30se c
Select the Aux1 parameters
Robot mode: Select Yes to
assign the AUX1 outlet to a
cleaning robot.
Backwash mode : Select Yes To
control a pneumatic backwash
push pull valve.
Backwash duration : Backwash
duration
O t h e r

Hide quick links: