Installation, restricted access to some specific settings
The settings which can only be accessed by the "Install" hidden menu are listed in Bold Italic.
1: In the Settings menu,
press simultaneously on ESC & ENTER for 3 seconds. The sub-menu Install menu appears at the bottom right of the screen
(automatically disappears after 120 minutes).
INTELLIPOOL
®
C
O
N
T
R
O
07/12/2013 15:23:48
Water temp.: +24.0°C ¥
pH:7.3
ORP:629mV
Cond: 56uS
3.51g/L
ESC
VALID
Menu Settings
pH/Disinfect./Temp
pH
Disinfectant
Temperature
Units (language and °F/°C selection)
Time
Radio
Register equipment
Register remote control
Reset remote control
Menu Lighting
Manual / Program / Off
Colour: 0
Schedule settings
Filtration menu
Auto /On / Off / Program
Shock
Filtration setting
Cleaning
Filtration operation time slot
Menu Aux1 (
Manual / Horloge / Off
Timer: 10'
Program settings
INTELLIPOOL
L
C
O
SE T T ING S MEN U
- p H/Dis i nfec t. /Tem p
- La ng ua g e -Ti m e
- R a di o
ESC
Auto/Off
pH+/pH- define
Setpoint
Priming
Auto/Off
Setpoint
Priming
Auto/Off
Setpoint
invisible if AUX1 is programmed as backwash auto
®
N
T
R
O
L
VALID
3 s
Install menu
Electrolyser/Other
Filtration
Anti-freezing: + 3 °C
Eco= (Standard -30%)
Turbo= (Standard +30%)
pH
Injection time: 15 sec
Temperature min.: 16 °C
Daily volume, max.: 0.2 L
Disinfect.
Injection time: 15 sec
Temperature min.: 14 °C
Volume days Max: 0.5 L
Aux1
Robot mode: No
Backwash mode: YES
Backwash duration: 10 sec
Default values
The settings of the rotation speeds of the IntelliFlo can be
accessed via the IntelliFlo menu at www.intellipool.eu
)
INTELLIPOOL
®
C
O
N
T
R
O
L
SE T T IN GS M EN U
- pH/Disinfec t./Tem p
- La ngua ge -Time
- R a dio
-I nsta l
ESC
VALID
17