IP Installation on the MVME162P2

The MVME162P2 accommodates up to two IndustryPack (IP) modules.
Install the IP modules on the MVME162P2 as follows:
1. Each IP module has two 50-pin connectors that plug into two
2. Two additional 50-pin connectors (J3 and J4) are provided behind

MVME162P2 Installation

With EPROM and IP modules installed and headers or switches properly
configured, proceed as follows to install the MVME162P2 in a VME
chassis:
1. Turn all equipment power OFF and disconnect the power cable
http://www.motorola.com/computer/literature
corresponding 50-pin connectors on the MVME162P2: J5/J6, J7/J8.
See Figure 2-1 for the MVME162P2 connector locations.
– Orient the IP module(s) so that the tapered connector shells mate
properly. Plug IP_a into connectors J5 and J6; plug IP_b into J7
and J8. If a double-sized IP is used, plug IP_ab into J5, J6, J7,
and J8.
the MVME162P2 front panel for external cabling connections to the
IP modules. There is a one-to-one correspondence between the
signals on the cabling connectors and the signals on the associated
IP connectors (i.e., J4 has the same IP_a signals as J5; J3 has the
same IP_b signals as J7.
– Connect user-supplied 50-pin cables to J3 and J4 as needed.
(Because of the varying requirements for each different kind of
IP, Motorola does not supply these cables.)
– Bring the IP cables out the narrow slots in the MVME162P2
front panel and attach them to the appropriate external
equipment, depending on the nature of the particular IP(s).
from the AC power source.
Installation Instructions