IP D/C/B/A Interrupt 1 Control = 00000000?
Define the interrupt control requirements for the IP modules, channel 1:
If you have specified environmental parameters that will cause an overlap
!
condition, a warning message will appear before the environmental
parameters are saved in NVRAM. The important information about each
Caution
configurable element in the memory map is displayed, showing where any
overlap conditions exist. This allows you to quickly identify and correct an
undesirable configuration before it is saved.
If an undesirable configuration already exists, you may wish to restore the
factory defaults with env;d <CR>.
ENV warning example:
WARNING: Memory MAP Overlap Condition Exists
S-Address
E-Address
$00000000
$FFFFFFFF
$FFE00000
$FFE7FFFF
$01000000
$EFFFFFFF
$00000000
$00000000
$00000000
$00FFFFFF
$00000000
$00000000
$F0000000
$FF7FFFFF
$FFFF0000
$FFFFFFFF
$FF800000
$FFBFFFFF
$FFF00000
$FFFEFFFF
$00000000
$00000000
$00000000
$00000000
$00000000
$00000000
http://www.motorola.com/computer/literature
Bits
IP
Register Address
31-24
D
FFFBC017
23-16
C
FFFBC015
15-08
B
FFFBC013
07-00
A
FFFBC011
Enable Overlap M-Type
Yes
Yes
Master
Yes
Yes
Master
Yes
Yes
Master
No
No
Master
Yes
Yes
Master
No
No
Master
Yes
Yes
Master
Yes
Yes
Master
Yes
Yes
Master
Yes
Yes
Master
No
No
Master
No
No
Master
No
No
Master
ENV - Set Environment
Memory-MAP-Name
Local Memory (Dynamic RAM)
Static RAM
VMEbus Master #1
VMEbus Master #2
VMEbus Master #3
VMEbus Master #4
VMEbus F Pages (A24/A32)
VMEbus Short I/O (A16)
Flash/PROM
Local I/O
Industry Pack A
Industry Pack B
Industry Pack C
3