Solving Startup Problems

In the event of difficulty with your MVME162P2 VME embedded
controller, try the simple troubleshooting steps on the following pages
before calling for help or sending the board back for repair. Some of the
procedures will return the board to the factory debugger environment. (The
board was tested under these conditions before it left the factory.) The self-
tests may not run in all user-customized environments.

Table B-1. Troubleshooting MVME162P2 Boards

Condition
I. Nothing works, no
display on the
terminal.
BTroubleshooting
Possible Problem
A. If the
(or
RUN
) LED is not
FUSE
lit, the board may
not be getting
correct power.
B. If the LEDs are
lit, the board may
be in the wrong
slot.
C. The "system
console"
terminal may be
configured
incorrectly.
Try This:
1. Make sure the system is plugged in.
2. Check that the board is securely installed in its backplane
or chassis.
3. Check that all necessary cables are connected to the
board, per this manual.
4. Check for compliance with System Considerations, as
described in this manual.
5. Review the Installation and Startup procedures, as
described in this manual. They include a step-by-step
powerup routine. Try it.
1. For VMEmodules, the processor module (controller)
should be in the first (leftmost) slot.
2. Also check that the "system controller" function on the
board is enabled, per this manual.
Configure the system console terminal as described in this
manual.
B
B-1