Min Angle (Id=10052); Min Speed Delta (Id=10053); Min Saved Records (Id=10054); Send Period (Id=10055) - Teltonika TMT250 User Manual

Hide thumbs Also See for TMT250:
Table of Contents

Advertisement

Minimum
Maximum
value
value
0
65535

7.5.2.3 Min Angle (ID=10052)

This parameter indicates angle in degrees in order to acquire a new record. If angle
difference between last recorded coordinate and current position is greater than defined value,
new record is stored. This parameter is operational, when speed is higher than 10km/h. If value
is 0 it means no records by min angle will be saved.
Minimum
Maximum
value
value
0
180

7.5.2.4 Min Speed Delta (ID=10053)

This parameter indicates speed difference in order to acquire a new record. If speed
difference between last recorded coordinate and current position is greater than defined value,
new record is stored. If value is 0 it means no records by min speed delta will be saved.
Minimum
Maximum
value
value
0
255

7.5.2.5 Min Saved Records (ID=10054)

This parameter defines minimum number of records in one data packet that can be sent to
server. It has higher priority than Data Send Period (ID=10055).
Minimum
Maximum
value
value
1
255
Default value
Goes with (depends on)
Min Period (ID=10050)
100
Min Speed Delta (ID=10053)
Min Saved Records (ID=10054)

Send Period (ID=10055)

Default value
Goes with (depends on)
Min Period (ID=10050)
Min Distance (ID=10051)
10
Min Speed Delta (ID=10053)
Min Saved Records (ID=10054)
Send Period (ID=10055)
Default value
Goes with (depends on)
Min Period (ID=10050)
Min Distance (ID=10051)
10
Min Saved Records (ID=10054)
Send Period (ID=10055)
Default value
Goes with (depends on)
Min Period (ID=10050)
Min Distance (ID=10051)
1
Min Speed Delta (ID=10053)
Send Period (ID=10055)
70
parameters
Min Angle (ID=10052)
parameters
parameters
Min Angle (ID=10052)
parameters
Min Angle (ID=10052)
Value type
Uint16
Value type
Uint8
Value type
Uint8
Value type
Uint8

Advertisement

Table of Contents
loading

Table of Contents