Cleaning And Maintenance; Cleaning; Cleaning Personnel; Decommissioning And Cleaning - WAGNER Jaguar 75-150 Operating Manual

Icebreaker piston pumps
Table of Contents

Advertisement

VERSION 02/2018
8

CLEANING AND MAINTENANCE

8.1

CLEANING

8.1.1 CLEANING PERSONNEL

Cleaning work should be undertaken regularly and carefully by qualified and trained
personnel. They should be informed of specific hazards during their training. The following
hazards may arise during cleaning work:
− Health hazard from inhaling solvent vapors.
− Use of unsuitable cleaning tools and aids.

8.1.2 DECOMMISSIONING AND CLEANING

The device should be cleaned for maintenance purposes, etc. Ensure that no remaining
product dries on and sticks to the device.
Procedure
1. Carry out work interruption
2. Carry out the basic flushing
3. Empty system in a controlled manner
4. Service spray gun in accordance to its operating instructions.
5. Clean and check the suction system and the suction filter.
6. When using a product filter, check filter insert and filter housing and clean or replace
them.
Chapter
8.2.6
7. Clean the outside of the system.
8. Fully assemble the system.
9. Check fill level of the separating agent
10. Fill the system with flushing agent in accordance with Chapter 8.2.5.

8.1.3 LONG-TERM STORAGE

When storing the device for longer periods of time, it is necessary to thoroughly clean it
and protect it from corrosion. Replace the water or solvent in the product pump with a
suitable preservative, fill separating agent cup with separating agent.
Procedure
1. Perform points 1 to 8 in Chapter 8.1.2.
2. Fill the system with preservative in accordance with Chapter 8.2.5.
3. Empty the system in a controlled manner in accordance with Chapter
the openings.
ORDER NUMBER DOC 2340282
Chapter 7.4.
Chapter 7.5.
Chapter 8.2.4.
Chapter 8.2.3.1.
IceBreaker 150-300 cm
8.2.4
and seal