All information and specifications can be modified without prior notice The Delta part number can be found on the type plate of the All translations of this manual not authorized by Delta Electronics inverter The Product Version is shown by the last letters of the (Netherlands) B.V.
► Do not remove the cover if water might enter the inverter ► After work is completed, ensure that the cover is properly replaced and screwed in Check that the cover is properly sealed Quick Installation Guide for Solar Power Inverter M50A_12s EU V4 EN 2018-10-24...
Belgien Deutschland Österreich Schweiz Check the delivery for completeness and all com- ponents for damage before starting installation work Do not use any damaged components Keep the packaging Quick Installation Guide for Solar Power Inverter M50A_12s EU V4 EN 2018-10-24...
Fuse box with string fuses and overvoltage conductors Fans Air inlets Type plate Electrical connections Grounding connection DC connections AC/DC disconnector Communication port 1 AC connection Communications port 2 (not used) Quick Installation Guide for Solar Power Inverter M50A_12s EU V4 EN 2018-10-24...
WEEE mark The inverter must not be disposed of as standard household waste, but in accordance with the applicable elec- tronic waste disposal regulations of your country or region Quick Installation Guide for Solar Power Inverter M50A_12s EU V4 EN 2018-10-24...
In this case, cover the air inlets without impeding the air flow through the inverter. Regularly clean and test the cool- ing system, see Installation and Operating Instructions Quick Installation Guide for Solar Power Inverter M50A_12s EU V4 EN 2018-10-24...
Transporting and lifting the inverter WARNING Heavy weight The inverter is very heavy ► The inverter must be lifted and carried by at least 3 people or using appropriate lifting gear Quick Installation Guide for Solar Power Inverter M50A_12s EU V4 EN 2018-10-24...
6 or 12 M6 screws Check that the inverter is correctly positioned at the lower end of the wall / mounting system Mount the inverter on the mounting plate Quick Installation Guide for Solar Power Inverter M50A_12s EU V4 EN 2018-10-24...
Warning washer, washer, and lock washer are already mounted on Two voltage sources Prior to any work, disconnect the inverter - Distribution network both sources - PV modules Quick Installation Guide for Solar Power Inverter M50A_12s EU V4 EN 2018-10-24...
The inverter must be grounded via the PE conductor To do this, connect the PE conductor of the AC cable to the AC plug pin provided for that purpose Quick Installation Guide for Solar Power Inverter M50A_12s EU V4 EN 2018-10-24...
Page 13
Remove the insulation from the cable and wires Do not twist the wire ends because this reduces the contact sur- face area with the wire end sleeves 22 ± 2 mm Quick Installation Guide for Solar Power Inverter M50A_12s EU V4 EN 2018-10-24...
Page 14
D1 + D2 + D3 13 0 14 0 Nm 3 5 mm (with 38 mm wire cross-section) D1 + D2 + D3 12 Nm 3 5 mm Quick Installation Guide for Solar Power Inverter M50A_12s EU V4 EN 2018-10-24...
Page 15
AC connection type must be changed using the display to 3P3W after commissioning, see “AC connec- tion type”, page 23 Turn the AC/DC disconnector to the OFF position Quick Installation Guide for Solar Power Inverter M50A_12s EU V4 EN 2018-10-24...
DC connections with the rubber plugs that are attached to the DC connections ► In order to start the inverter, DC voltage must run through both DC inputs! Quick Installation Guide for Solar Power Inverter M50A_12s EU V4 EN 2018-10-24...
Page 17
5 5-9 32 0016P0001-UR 32 0011P0001-UR 1 5 / 2 5 5 5-9 32 0013P0001-UR 32 0015P0001-UR 4 / 6 5 5-9 32 0017P0001-UR 1) Included in delivery Quick Installation Guide for Solar Power Inverter M50A_12s EU V4 EN 2018-10-24...
Terminal pairs 3/4 or 5/6 can be used It doesn't matter which terminal pair is used The second terminal pair is only required when connecting several inverters via RS485 VCC (+12 V; 0 5 A) RS485 termination resistor Quick Installation Guide for Solar Power Inverter M50A_12s EU V4 EN 2018-10-24...
Page 19
► Do not use GND and VCC ► If the cable shield is used for providing lightning protection then the housing of only one inverter in the RS485 chain should be grounded Quick Installation Guide for Solar Power Inverter M50A_12s EU V4 EN 2018-10-24...
After commissioning, an event can be assigned to the dry con- V1 + K5 Reserved tacts on the display, see “Dry contacts”, page 25 V1 + K6 Reserved Quick Installation Guide for Solar Power Inverter M50A_12s EU V4 EN 2018-10-24...
1 2 . J u n 2 0 1 6 1 7 : 1 5 Repeat the procedure for the other settings Quick Installation Guide for Solar Power Inverter M50A_12s EU V4 EN 2018-10-24...
Use the buttons to configure the value and then press the button S e t t i n g I D : I D = 0 0 1 Quick Installation Guide for Solar Power Inverter M50A_12s EU V4 EN 2018-10-24...
5 5 0 0 0 W R e t u r n t o F a c t o r y Use the buttons to configure a value and then press the button Quick Installation Guide for Solar Power Inverter M50A_12s EU V4 EN 2018-10-24...
See “Connecting digital inputs, external shutdown and dry contacts (optional)”, page 20 F a n F a i l for the available options I n s u l a t i o n Quick Installation Guide for Solar Power Inverter M50A_12s EU V4 EN 2018-10-24...
0 8 ind Total harmonic distortion <3% DC injection <0 5% at nominal current Power loss in night mode <2 5 W Overvoltage category Surge protection devices Type 2, replaceable Quick Installation Guide for Solar Power Inverter M50A_12s EU V4 EN 2018-10-24...
Page 27
Can occur under the following conditions: DC input voltage > 580 V; symmetrical load; ambient temperature < 25 °C. AC voltage and frequency range are programmed using the corresponding country specifications. Quick Installation Guide for Solar Power Inverter M50A_12s EU V4 EN 2018-10-24...