11 Technical Data
Model
Enclosure
Operating temperature
Operating Altitude
Relative humidity
Environmental category
Inverter topology
Safety class
Pollution degree
Overvoltage category
Flicker impedance
Three-phase combinations
Max. input voltage
Operating voltage range
MPP range (rated power)
Normal voltage
MPP tracker
Maximum input current
Max. short circuit current
per MPPT
Max. inverter backfeed
current to the array
Startup voltage
Input connection
1) Testing to multiple inverter combinations as per AS/NZS 4777.2:2020
Section 5 has not been conducted
Table 11-1 : Specifications
H5E_220
GENERAL
Powder-coated aluminium
-25~60°C, full power up to 40°C
0% – 95% non-condensing.
Outdoor, wet locations
Non-isolated (TL Topology)
Class I metal enclosure with protective earth
Internal: II, External: III
AC output: III, DC input: II
Z = 0.4 + j 0.25 Ω (total impedance)
DC INPUT (Solar side)
30-550Vdc
220-500Vdc
12Adc for each / 24Adc for total
H4, 2 pairs
51
< 2000m
No ¹
600 Vdc
350 Vdc
2
15 A
0A
35 Vdc