Maintenance
Operating Instructions 670/680 - 00.0 - 01/2017
Fig. 32: Draining the water condensation
(1) - Filter element
(2) - Water separator
To drain water condensation:
1.
Disconnect the machine from the compressed air supply.
2.
Place the collection tray under the drain screw (3).
3.
Loosen the drain screw (3) completely.
4.
Allow water to drain into the collection tray.
5.
Tighten the drain screw (3).
6.
Connect the machine to the compressed air supply.
(3) - Drain screw