Endress+Hauser Proline Promag 50H Manual page 40

Electromagnetic flow measuring system flow measurement of liquids in hygienic, food or process applications
Hide thumbs Also See for Proline Promag 50H:
Table of Contents

Advertisement

40
Process connections with aseptic gasket seal DN 40 to 100 (1½ to 4")
Weld socket for DIN
1.4404 / 316L
5*H**-U***********
L1
L
Weld socket for ODT/SMS
1.4404 / 316L
5*H**-V***********
L1
L
Clamp ISO 2852, Fig. 2
1.4404 / 316L
5*H**-W***********
L
Sensor
Fits to
DN
Piping
[mm]
DIN 11850
40
42 × 2
50
54 × 2
65
70 × 2
80
85 × 2
100
104 × 2
• – Fitting length for DN 40 to 65 = (2 × L) + 136 mm
– Fitting length for DN 80 to 100 = (2 × L) + 196 mm
• If pigs are used for cleaning, it is essential to take the inside diameters of
measuring tube and process connection (di) into account!
A0005541
Sensor
Fits to
DN
Piping
[mm]
OD/SMS
40
38.1 × 1.65
50
50.8 × 1.65
65
63.5 × 1.65
80
76.2 × 1.65
100
101.6 × 1.65
• – Fitting length for DN 40 to 65 = (2 × L) + 136 mm
– Fitting length for DN 80 to 100 = (2 × L) + 196 mm
• If pigs are used for cleaning, it is essential to take the inside diameters of
measuring tube and process connection (di) into account!
A0005541
Sensor
Fits to
piping
DN
ISO 2037 /
[mm]
BS 4825-1
40
38.0 × 1.6
50
51.0 × 1.6
65
63.5 × 1.6
80
76.1 × 1.6
100
101.6 × 2.0
• – Fitting length for DN 40 to 65 = (2 × L) + 136 mm
– Fitting length for DN 80 to 100 = (2 × L) + 196 mm
• If pigs are used for cleaning, it is essential to take the inside diameters of
A0005544
measuring tube and process connection (di) into account!
Proline Promag 50H, 53H
di
G
D
L
[mm]
[mm]
[mm]
[mm]
38.0
43
92
42
50.0
55
105
42
66.0
72
121
42
81.0
87
147
42
100.0
106
168
42
di
G
D
L
[mm]
[mm]
[mm]
[mm]
35.3
40
92
42
48.1
55
105
42
59.9
66
121
42
72.6
79
147
42
97.5
104
168
42
Clamp
di
G
D
ISO 2852
Diameter
[mm]
[mm]
[mm]
[mm]
38.0
35.6
50.5
92
51.0
48.6
64.0
105
63.5
60.3
77.5
121
76.1
72.9
91.0
147
101.6
97.6
119.0
168
Endress+Hauser
L1
LK
[mm]
[mm]
19
71.0
19
83.5
21
100.0
24
121.0
24
141.5
L1
LK
[mm]
[mm]
19
71.0
19
83.5
21
100.0
24
121.0
24
141.5
L
LK
[mm]
[mm]
68.5
71.0
68.5
83.5
68.5
100.0
68.5
121.0
68.5
141.5

Hide quick links: