1-1 (Page 3 Of 3). Command Reject Reference Codes - IBM 9348 Service Information

Table of Contents

Advertisement

tic int
I
code
Figure
1-1 (Page 3 of 3). Command Reject Reference Codes
Operator
21 F8063
tic int
code
Action
Test 38 was run with more steps entered than are permitted. Enter the
correct number of steps and attempt the test again.
Operator
21 F8063
Probable
Cause
75%
20
O / O
Ref.
Code
001 5
Part Number
Operator
21 F8063
4%
75
O / O
20 %
4%
tic int
2%
code
I
If this reference code continues to occur, exchange the FRU. If the ref-
erence code continues to occur, contact your next level of support.
The system has requested a density that is not available on the tape
unit. Select 1600 or 6250 bits per inch and attempt the operation
again.
95%
2
O / O
21 F8063
21 F7926
tic int
If this reference code continues to occur, exchange the FRU and
attempt the operation again to verify the repair. If the reference code
continues to occur, contact your next level of support.
A test was run to exercise a processor but an illegal processor was
selected. Correct the test and attempt the operation again.
tic int
code
If this reference code continues to occur, exchange the FRU. If the ref-
erence code continues to occur, contact your next level of support.
The system has requested a write record length that is more than is
permitted by the tape unit. Select a correct record length and attempt
the operation again.
If this reference code continues to occur, exchange the FRUs as
needed. Attempt the test again after each FRU is exchanged to verify
the repair. If the reference code continues to occur, contact your next
level of support.
The system has requested data from the buffer when no data was
available. Correct the command and attempt the operation again.
If this reference code continues to occur, exchange the FRUs as
needed. Attempt the operation again after each FRU is exchanged to
verify the repair. If the reference code continues to occur, contact
your next level of support.
21 F7926
O0lD
1
21F8063
The system attempted to put data into the buffer when the buffer was
full. Correct the command and attempt the operation again.
Lic int
code
Tape
21 F8063
21 F7926
If this reference code continues to occur, exchange the FRUs as
needed. Attempt the operation again after each FRU is exchanged to
verify the repair. If the reference code continues to occur, contact
your next level of support.
Test 129 was run with a defective configuration tape. This problem
may be caused by a bad tape or a dirty tape path. Clean the tape path;
see "Cleaning Procedure" on page 4-3. Load a tape that is known to
be good and attempt the operation again with a configuration tape that
is known to be good.
If this reference code continues to occur, exchange the FRUs as
needed. Attempt the operation again after each FRU is exchanged to
verify the repair.
Chapter
1.
Analyzing Problems
1-5