F-Range Type L-850C Style 3 Inset Lights
Cleaning Light Channel and
Prism (contd.)
Retorquing Mounting Bolts
Figure 4-1 Sequence for Torquing Mounting Bolts
2006 ADB Airfield Solutions, Incorporated
All rights reserved
2. Clean the outer surface of the prism (3) using liquid glass
cleaner. If the prism is coated with a substance impervious to the
cleaner, apply a suitable solvent sparingly with a wad of cotton or
a patch of cloth. After the solvent has acted, remove the
softened coating with a clean piece of cotton or cloth. Dry the
prism with gently, dry, oil-free compressed air at a pressure no
greater than 10 psi (69 KNt/m
remaining cleaner.
When retorquing mounting bolts, apply one drop of Grade AV Loctite
to each of the six 3.8-inch- (9.525-mm-) diameter mounting bolts.
Torque the bolts to 185 5 inch-pounds (20.902 0.565 Nt-m).
Torque the bolts across the corners.
See Figure 4-1. To torque the outer bolts across corners, tighten
bolts in noted sequence: #1 and #4, then #2 and #5, then #3 and #6.
NOTE: Applying more than one drop of Loctite to the screw and bolt
threads will create future difficulty in removal of the bolts.
NOTE: After several relampings, threaded holes may accumulate
with dirt and excessive Loctite. If this occurs, screws may not seat
properly. Clean holes with light weight oil or diesel fuel using a small
fiber brush. Wipe the holes clean with alcohol to remove all oil or
diesel fuel and dirt. Clean with dry, oil-free, low-pressure air.
96A0285D
Issued 04/13
Maintenance
) to evaporate or remove all
2
Page 4-3