Set Escape - Compaq AlphaServer DS10 Reference Manual

Hide thumbs Also See for AlphaServer DS10:
Table of Contents

Advertisement

4.14.18 set escape

The set escape command changes the escape sequence used for
invoking the RMC.
The escape sequence can be any character string, not to exceed 14 characters. A
typical sequence consists of two or more control characters. It is recommended
that control characters be used in preference to ASCII characters. Use the
status command to verify the escape sequence.
Be sure to record the new escape sequence. If you forget the escape sequence,
you must reset the RMC to the factory defaults. See Section 4.12 for
information on setting the RMC to the factory defaults.
The following example consists of two instances of the Esc key and the letters
"FUN." The "F" is not displayed when you set the sequence because it is
preceded by the escape character. Enter the status command to see the new
escape sequence.
Syntax:
set escape
Example:
TI94‡sˆÂs‡qi„s
A‡qi„sÂUs…‰s‚qs0‰‚
TI94‡ˆiˆ‰‡



A‡qi„sÂUs…‰s‚qs0ÂfcfcBWP
Remote Management Console
4-33