Appendix; Center Winder Settings - Danfoss VLT Center Winder MCO 352 Operating Instructions Manual

Table of Contents

Advertisement

®
VLT
Center Winder MCO 352

7 Appendix

7.1.1 Center Winder Settings

Par. No.
Parameter Description
Basic Winder Settings
19-01
Winder Mode Selection
19-02
Tension Set-Point
19-03
Taper Set-Point
19-04
Partial Roll Diameter Value
19-05
Smallest Core Used
19-06
Secondary Core
19-07
Winder Jog Speed
19-08
TLD Low Limit
19-09
TLD High Limit
19-10
TLD Out of Range Timer
19-11
TLD Timer Start Value
19-12
End of Roll Detector
19-13
Initial Diameter Measurement
19-14
Diameter Measurement Input
19-15
Reading at Core
19-16
Reading at Full Roll
19-19
Tension Set-Point Input
19-20
Taper Set-Point Input
19-21
Tension Feedback Input
19-22
Tension Feedback Type
19-23
Discrete Functions Source
19-24
Line Speed Scale
19-25
Speed Match Scale
19-26
Winder Speed Scale
19-27
Diameter Change Rate
19-28
Tapered Tension Change Rate
19-29
Diameter Calculator Minimum Speed
19-30
Line Acceleration Feed-Forward
19-31
Velocity Sampling Time (ms)
Tension PID Settings
19-40
Tension PID Maximum Contribution
19-41
PID Effect Verses Diameter
19-42
PID Proportional Gain
19-43
PID Derivative Time
19-44
PID Integral Time
19-45
PID Integral Limit
19-47
PID Der. Gain Limit
19-48
PID Anti Wind-up
19-49
Speed Loop Prop Min.
19-50
Speed Loop Prop Max.
19-51
Save Speed Prop Values
19-6* Command Parameters
19-61
Over Under Winding
19-62
Winder Jog Reverse
19-63
Winder Jog Forward
19-64
New Diameter Select
19-65
Tension On/Off
19-66
Mat Select
19-67
Core Select
19-68
Diameter Reset
19-9* Read Only Application Parameters
19-92
Winder Software Version
19-93
Winder Error Status
19-94
Program Loop Scan Time
19-95
Winder Speed Counts
19-96
Line Speed Counts
19-97
Diameter Size
19-98
Tapered Tension Set-Point
19-99
Tension Feedback
Default Value
[0] Rewinder
0
0
5000
5000
5000
0
0
0
1
0
0
[0] Set diameter when
diameter reset
[1] Input 53
0
0
[0] Par. 19-02
[0] Par. 19-03
[1] Input 53
[0] Load cell
[1] Par. 19-61 to 19-68 TRUE
200
500
200
1
1
500
0
50
0
0
0
0
10
0
1000
[0] Anti Wind-up disa-
bled
0
0
[0] No Function
[0] Over Winding
[0] No Function
[0] No Function
[0] No Function
[0] Turns tension off
1
[0] Core 1
[0] Core 1
-
-
-
-
-
-
-
-
®
MG.33.T1.02 - VLT
is a registered Danfoss trademark
Changes Dur-
4 set-up
Conversion
ing Operation
Index
TRUE
-
-
TRUE
-
-
TRUE
-
-
TRUE
-
-
TRUE
-
-
TRUE
-
-
TRUE
-
-
TRUE
-
-
TRUE
-
-
TRUE
-
-
TRUE
-
-
TRUE
-
-
TRUE
-
-
TRUE
-
-
TRUE
-
-
TRUE
-
-
TRUE
-
-
TRUE
-
-
TRUE
-
-
TRUE
-
-
-
-
TRUE
-
-
TRUE
-
-
TRUE
-
-
TRUE
-
-
TRUE
-
-
TRUE
-
-
TRUE
-
-
TRUE
-
-
TRUE
-
-
TRUE
-
-
TRUE
-
-
TRUE
-
-
TRUE
-
-
TRUE
-
-
TRUE
-
-
TRUE
-
-
TRUE
-
-
TRUE
-
-
TRUE
-
-
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
read only
No
0
read only
No
0
read only
No
0
read only
No
0
read only
No
0
read only
No
0
read only
No
0
read only
No
0
7 Appendix
Type
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
7
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Int32
Int32
Int32
Int32
Int32
Int32
Int32
Int32
35