6 Troubleshooting

Parameter 19-93 indicates the error status of the Center Winder Controller. Several different conditions can be detected.
NO ALARM
TENSION LIMIT DETECTED
FC ALARM
MCO305 ERROR
QSTOP
LOCAL MODE
Table 6.1: Center winder error, par. 19-93
Turning the tension off resets all fault conditions while in remote mode.
All messages are shown in the LCP display of the FC 300 in short and in the APOSS software in plain text.
You can find brief information on the error messages in the table or detailed information in the following section.
The tables contain the messages in numerical order. Letters following a % sign represent variables which can be used in plain text at the corresponding
locations
Error no
Error Text
103
Illegal axis num.
105
Error not reset
106
Home not done
107
Home vel. zero
108
Position error
109
Index not found
110
Unknown cmm.
111
SW end limit
112
Unknown param.
113
FC not enabled
114
Too many loops
115
Par. save failed
116
Param. memory
117
Progr. memory
118
Reset by CPU
119
User abort
125
HW end limit
149
Too many inter.
150
No ext. 24V
151
Too many gosub
152
Too many return
154
D. out overload
155
LINK failed
162
Memory error
170
Array size (DIM)
171
Array too small
179
Waitndx timeout
184
Too many ontime
187
Out of memory
190
Memory locked
191
Illegal cam array
192
Encoder error
199
Internal MCO fault
[0]
[1]
[2]
[3]
[4]
[5]
Description
Axes not in system
Error not cleared
Failed to move to HOME position
Home was executed with Home Velocity set to zero
Position error
Index pulse (encoder) not found
Unknow command
Software end limit activated
Illegal parameter number
FC 300 is not ready but the PID controller is active
Too many nested loops
Parameter save failed
Parameters in memory are corrupted
Programs in memory are corrupted
Reset by CPU
User abort
HQ end limit activated
Too many interrupt functions
External supply is missing
Too many nested GOSUB commands
Too many RETURN commands
Digital Output overloaded
LINKGPAR command failed
Error in veryfying; EEPROM: address % defect
Error in DIM command
Attempt was made to cross array bounds
Timeout while waiting for index
Too many time interrupts
No more room for variables
The program memory is write-protected
Curve array wrong
Encoder error
Internal MCO fault
®