Preset Winder Function Parameters - Danfoss VLT Center Winder MCO 352 Operating Instructions Manual

Table of Contents

Advertisement

5 Center Winder Calibration

5.1.2 Preset Winder Function Parameters

NB!
The following procedure assumes that digital input control will be used. If serial control will be used, issue logic commands by writing
values to the appropriate parameter (19-61 – 19-68).
Par.
Function
3-41
Ramp-up Time 1
3-42
Ramp-down Time 1
19-01
Winder Mode
19-02
Tension Set Point
5
19-03
Taper Set Point
19-04
Partial roll diameter value
19-05
Smallest core to be used
19-06
Secondary core
19-07
Winder jog speed %
19-08
TLD Low Limit
19-09
TLD High Limit
19-10
TLD Out of Range Timer
19-11
TLD Timer Start Value
19-12
Full Roll Detector
19-13
Initial Diameter Measurement
19-14
Diameter Measurement Input
19-15
Reading at Core x 100
19-16
Reading at Full Roll x 100
19-19
Tension Setpoint Input
19-20
Taper Setpoint Input
19-21
Tension Feedback Input
19-22
Tension Feedback Type
19-23
Discrete Functions Source
19-24
Line Speed
19-25
Scale Speed
19-26
Match Winder Speed
19-27
Scale Diameter Change Rate
19-28
Tapered Tension Change Rate
19-29
Diameter Calculator Minimum Speed
19-30
Acceleration Feed-Forward
19-31
Velocity Sampling Time (ms)
19-40
PID Limit
19-41
PID Profiles
19-42
PID Proportional Gain
19-43
PID Derivative Time
19-44
PID Integral Time
19-45
PID Integral Limit
19-47
PID Der. Gain Max
19-48
PID Anti Wind-Up
19-49
Speed Loop Prop Min.
19-50
Speed Loop Prop Max.
19-51
Save Values
28
Range
0.01 – 3600.00 s
0.01 – 3600.00 s
0 – 1
0 – 1000
-1100 – 1100
5000 – 100000
5000 – 100000
5000 – 100000
0 – 100
-200 – 2000
0 – 2200
1 – 200
-500 – 0
-100 – 100000
0 – 1
1 – 2
-1100 – 1100
-1111 – 2111
0 – 2
0 – 2
1 – 2
0 – 1
1 – 2
200 – 18000
500 – 10000
200 – 18000
1 – 50
1 – 10
500 – 200000
-20000 – 20000
50 – 500
0 – 200000
0 – 10000
0 – 5000
0 – 1000
10 – 20100
0 – 100000
1000 – 50000
0 – 1
0 – 10000
0 – 10000
0 – 1
®
MG.33.T1.02 - VLT
is a registered Danfoss trademark
®
VLT
Center Winder MCO 352
Value to preset to
0.05 s
0.05 s
Set according to application
0
0
Calculate if used
Calculate Calculate if used
5
-200
2200
200
-200
100000 for rewind, 0 for unwind
Set based on application
Set based on application
Will Be Determined if used
Will Be Determined if used
Set according to application
Set according to application
Set according to application
Set according to application
2
Will Be Determined
Will Be Determined
Will Be Determined
20
2
500
0
50
0