4 How to Install
19-50 Speed Loop Pro Max.
Range:
0
[0 – 10000]
19-51 Save Speed Prop Values
Option:
4
[0] *
No function
[1]
Initiates saving
19-61 Over Under Winding
Option:
[0] *
Selects over winding
[1]
Selects under winding
19-62 Winder Jog Reverse
Option:
[0] *
No function
[1]
Selects winder jog reverse
19-63 Winder Jog Forward
Option:
[0] *
No function
[1]
Selects winder jog forward
19-64 New Diameter Select
Option:
[0] *
No function
[1]
Preset diameter to programmed val-
ue in par. 19-04
19-65 Tension On/Off
Option:
[0] *
Turns tension off
[1]
Turns tension on
24
Function:
A value of 100 used in parameter 19-49 or 19-50 will be translated to 0.100 in parameter 7-02.
Speed Loop Prop Gain used at full roll diameter. More information see parameter 19-49.
Function:
Allows saving speed proportional gain values and tension PID values in memory. The values should
be saved after completing changes to parameters 19-41 – 19-50. The values are automatically
stored when a different material is selected.
Initiates the save. The value will return to 0 after the save has completed. This function can only
be used when tension if OFF.
Function:
Parameter 19-61 - 19-68 can replace the digital Inputs 1-8 when parameter 19-23 is programmed
to 1. When this is the case the digital inputs are not used and their functions are transferred to
parameter 19-61 through 19-68. These parameters act just the same as if they were the digital
inputs with values of 0 and 1.
Function:
See Parameter 19-61.
Function:
See Parameter 19-61.
Function:
See Parameter 19-61.
Diameter is preset to the value programmed in parameter 19-04 when parameter 19-68 is changed
to 1.
Function:
See Parameter 19-61.
®
MG.33.T1.02 - VLT
is a registered Danfoss trademark
®
VLT
Center Winder MCO 352