15-** Drive Information
Par.
Parameter description
No. #
15-0* Operating Data
15-00 Operating Hours
15-01 Running Hours
15-02 kWh Counter
15-03 Power Up's
15-04 Over Temp's
15-05 Over Volt's
15-06 Reset kWh Counter
Reset
Running
15-07
Counter
15-1* Data Log Settings
15-10 Logging Source
15-11 Logging Interval
15-12 Trigger Event
15-13 Logging Mode
15-14 Samples Before Trigger
15-2* Historic Log
15-20 Historic Log: Event
15-21 Historic Log: Value
15-22 Historic Log: Time
15-3* Fault Log
15-30 Fault Log: Error Code
15-31 Fault Log: Value
15-32 Fault Log: Time
15-4* Drive Identification
15-40 FC Type
15-41 Power Section
15-42 Voltage
15-43 Software Version
15-44 Ordered Typecode String
15-45 Actual Typecode String
Frequency Converter Or-
15-46
dering No
15-47 Power Card Ordering No
15-48 LCP Id No
15-49 SW ID Control Card
15-50 SW ID Power Card
Frequency Converter Seri-
15-51
al Number
15-53 Power Card Serial Number
15-6* Option Ident
15-60 Option Mounted
15-61 Option SW Version
15-62 Option Ordering No
15-63 Option Serial No
15-70 Option in Slot A
15-71 Slot A Option SW Version
15-72 Option in Slot B
15-73 Slot B Option SW Version
15-74 Option in Slot C0
15-75 Slot C0 Option SW Version
15-76 Option in Slot C1
15-77 Slot C1 Option SW Version
15-9* Parameter Info
15-92 Defined Parameters
15-93 Modified Parameters
15-99 Parameter Metadata
How to Programme
Default value (SR
- Size Related)
0 h
All set-ups
0 h
All set-ups
0 kWh
All set-ups
0
All set-ups
0
All set-ups
0
All set-ups
[0] Do not reset
All set-ups
Hours
[0] Do not reset
All set-ups
0
SR
[0] False
[0] Log always
50
0
All set-ups
0
All set-ups
0 ms
All set-ups
0
All set-ups
0
All set-ups
0 s
All set-ups
0
All set-ups
0
All set-ups
0
All set-ups
0
All set-ups
0
All set-ups
0
All set-ups
0
All set-ups
0
All set-ups
0
All set-ups
0
All set-ups
0
All set-ups
0
All set-ups
0
All set-ups
0
All set-ups
0
All set-ups
0
All set-ups
0
All set-ups
0
All set-ups
0
All set-ups
0
All set-ups
0
All set-ups
0
All set-ups
0
All set-ups
0
All set-ups
0
All set-ups
0
All set-ups
0
All set-ups
0
All set-ups
MG.33.A8.02 - VLT is a registered Danfoss trademark
4-set-up
FC 302
Change
only
during
operation
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
TRUE
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
1 set-up
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
Conver-
Type
sion
index
74
Uint32
74
Uint32
75
Uint32
0
Uint32
0
Uint16
0
Uint16
-
Uint8
-
Uint8
-
Uint16
-3
TimD
-
Uint8
-
Uint8
0
Uint8
0
Uint8
0
Uint32
-3
Uint32
0
Uint8
0
Int16
0
Uint32
0
VisStr[6]
0
VisStr[20]
0
VisStr[20]
0
VisStr[5]
0
VisStr[40]
0
VisStr[40]
0
VisStr[8]
0
VisStr[8]
0
VisStr[20]
0
VisStr[20]
0
VisStr[20]
0
VisStr[10]
0
VisStr[19]
0
VisStr[30]
0
VisStr[20]
0
VisStr[8]
0
VisStr[18]
0
VisStr[30]
0
VisStr[20]
0
VisStr[30]
0
VisStr[20]
0
VisStr[30]
0
VisStr[20]
0
VisStr[30]
0
VisStr[20]
0
Uint16
0
Uint16
0
Uint16
61