Description; Overview - Siemens SITRANS FC330 Operating Instructions Manual

Coriolis flowmeters
Table of Contents

Advertisement

Description

3.1

Overview

SITRANS Coriolis flowmeter systems consist of a transmitter and a sensor. The following table
lists the available combinations of transmitters and sensors.
Transmitter
FCT030
You can use the flowmeter for the following measuring tasks:
● Mass flow
● Volume flow
● Standard volume flow
● Density
● Medium temperature
● depending on product variants: fraction, including industry-specific fractions
Operate the device according to the specifications in section Technical data (Page 195).
The Coriolis flowmeter can be used in a number of system configurations:
● as a field mounted transmitter supplied with various optional inputs and outputs
● as part of a system environment, for example SIMATIC S7
SITRANS FC330
Operating Instructions, 01/2019, A5E44030648-AB
Communication modem
PC with SIMATIC PDM or similar application
SIMATIC PLC system with HART interface
Sensor type
FCS300
DN 15 to DN 150 (0.5" to 6")
3
21