Pressure - Temperature Ratings - Siemens SITRANS FC330 Operating Instructions Manual

Coriolis flowmeters
Table of Contents

Advertisement

Liquids of fluid group 1
● Pipelines according to Article 4 (a) (ii) First dash
Figure 11-3
Liquids of fluid group 2
● Pipelines according to Article 4 (a) (ii) Second dash
Figure 11-4
11.13

Pressure - temperature ratings

Pressure - temperature ratings are determined by process connection material and applicable
standards. The tables below detail the allowed maximum process pressure for sensor variants
with stainless steel and Hastelloy measuring tubes.
With two major exceptions, the pressure rating of the flow sensors is independent of the
process medium temperature. Design rules for flange connections in both the EN1092-1 and
ASME B16.5 standards dictate pressure derating with increasing temperature. The charts
below show the effect of process medium temperature on the pressure ratings for the flanges
within the product program.
SITRANS FC330
Operating Instructions, 01/2019, A5E44030648-AB
PS [bar]
1000
500
100
Article 3
Paragraph 3
10
1
0,5
25
0,1
1
10
Diagram 3
PS [bar]
1000
500
100
Article 3
Paragraph 3
10
1
0,5
0,1
1
10
Diagram 4
III
PS = 500
II
PS = 10
I
PS = 0,5
4000
100
1000
10000
DN
II
PS = 500
I
PS = 10
PS = 0,5
200
100
1000
10000
DN
Technical data
11.13 Pressure - temperature ratings
211

Advertisement

Table of Contents
loading

Table of Contents