Pneumatic; Port 1 And 2 (Thread Size G½ Or Npt½-14) - Festo MS6N-SV-***-E-ASIS Series Operating Instructions Manual

Soft-start/quick exhaust valve
Table of Contents

Advertisement

Available languages

Available languages

MS6(N)-SV-...-E-ASIS
Combination with service units of the MS series
Warning
Incorrectly installing the device in the service unit combination can impair the
MS6(N)-SV-...-E-ASIS safety function.
• Only devices that do not impair the pneumatic safety function – safe venting – may
be placed downstream of the MS6(N)-SV-...-E-ASIS.
If fitted together with one or several already present service units of the same series
Fig. 5 Assembly.
1. Remove the cover cap MS6-END 1, if on
hand, from the side to be combined (push up-
wards).
2. Place the module connectors MS6-MV 2 in
the grooves of the individual devices. A seal is
required between the individual units (in-
cluded in the scope of delivery, module con-
nector MS6-MV or mounting bracket
MS6-WPB).
3. Fasten the module connectors MS6-MV with
2 screws.
5.2

Pneumatic

5.2.1
Port 1 and 2 (thread size G½ or NPT½-14)
If using screw connectors with spanner size larger than SW24:
• Remove the cover cap MS6-END (push upwards), if on hand.
If using fittings:
• Observe the maximum screw-in depth of the connecting threads:
ISO 228
10.0 mm
Tab. 3
Max. screw-in depth
42
NPT
10.0 mm
Fig. 5
Assembly
Festo – MS6(N)-SV-...-E-ASIS – 1205NH English
1
2
max. 1.2 Nm

Advertisement