line 10
display reports
errors
Error display
CAN-PGV
Current
cap
error: pressure ->[
PG2, PG3, WG1,
WG2
error: pressure ]->
PG2, PG3
error: pressure ]->
pg2, pg3
set. ch.
invalid set
Warnings
display
Warning: pressure
PG2, PG3, WG1,
WG2
Warning: pressure
pg2, pg3, wg1, wg2
PGC-300 pressure monitoring
PG
WG
Pos : 19.26 /Steuer module--------------- Seitenumbr uch --------------- @ 0\mod_1197390577023_19.doc x @ 1454 @ @ 1
Cause
• connection to PGV is interrupted
• PGC is Master and does not have a RS 485
connection to the power source.
• torch is not correctly installed
• inlet pressure of used gases too low
• outlet pressure of used gases too high
+0,4bar cutting gas-reference pressure
• outlet pressure of used gases too low
-0,4 bar cutting gas-reference pressure
• there is no data set selected
• CNC has sent wrong gas combination
Cause
• outlet pressure of used gases too high
+0,3 bar reference pressure
• outlet pressure of used gases too low
-0,3 bar reference pressure
-0,4
-0,3
+0,3
-0,3
+0,3
Plasma gas control unit FlowControl-300
bar
+0,4
bar
Error
warning
reference pressure