Kjellberg SmartFocus 300 Short Instruction Manual page 98

Table of Contents

Advertisement

Plasma gas control unit FlowControl-300
Pos : 19.25 /Gas kons olen/FlowC ontrol/Fl owc ontrol-300/Betri ebs .-Sc hnei den @ 13\mod_1415961416934_19.doc x @ 210317 @ @ 1
line 1
1
set number:
only set numbers covered with data will be displayed
3
kind of material description
4
description of the comment
6
necessary cutting current (only in manual operation and PGC is master)
line 2
2
thickness
5
after using the key F1 - display of the record parameter opens itself (notice about
employed consumables and further cutting parameters)
lines 3 - 6
In these lines the ignition gas, cutting gas and swirl gases will be displayed. Cutting gases
PG 2-3 and swirl gases WG 1-2 are possible.
If one data set is selected the respective windows indicates the valid gases (line 4) for this
set, as well as cutting gas-reference pressure in Bar (line 5) and their cutting gas-actual
pressure in Bar (line 6). For gases that are not used the fields of the respective gas path are
blank.
In this case the pilot arc becomes ignited with the gas of the path PG1.
lines 7 - 8
Command line
Indications are given for possible commands, like: copying of the data set, repeated
transmission of paramters, gas test and process runs etc.
line 9
Information
„no data set on I/O" or „no free memory capacity available"