Fast data set
switchover
2
Data set selection
3
T gas purge 1
T gas purge 2
Fast data set switchover between two stored data sets
(at manual mode of PGC)
• by pressing button F3 or
• by CNC (via interface X102)
Default setting: CNC
data set selection
(at manual mode of PGC)
• by pressing button F2
F2-S  short protocol/ F2-L  long protocol
or
• by CNC (via interface X6)
The selected set number of CNC is shown at thr right side of this line.
No set number selcted: 0
This time determines the duration of the gas purge after each change of the
gas between two different cutting processes.
Standard setting gas purge time1 = 25 s
This time determines the duration of the gas purge between a cutting process
and a marking process.
If cutting gas and marking gas are identical (e.g. argon), is not blown through.
Standard setting = 5 s
Plasma gas control unit FlowControl-300